Mostrar el registro sencillo del ítem

dc.contributor.authorMerchán Corral, Rosa Pilar 
dc.contributor.authorSantos Sánchez, María Jesús 
dc.contributor.authorGarcía Ferrero, Judit
dc.contributor.authorMedina Domínguez, Alejandro 
dc.contributor.authorCalvo Hernández, Antonio 
dc.date.accessioned2021-03-24T11:42:16Z
dc.date.available2021-03-24T11:42:16Z
dc.date.issued2021
dc.identifier.issn1359-4311
dc.identifier.urihttp://hdl.handle.net/10366/145616
dc.description.abstract[EN]A hybrid central tower thermo-solar plant working with a gas turbine is simulated by means of an in-house developed model and software. The model considers the integration of all plant subsystems. The calculation of the heliostat solar field efficiency includes the main losses factors as blocking, shadowing, attenuation, interception, and cosine effect. The simulation considers a Brayton cycle for the power unit with irreversibilities in the compressor and turbine, and pressure drops in the heat absorption and extraction processes. A combustion chamber burning natural gas ensures an approximately constant power output. The model is flexible and precise. At the same time it is fast enough to perform sensitivity studies on the efficiency of any subsystem and the overall plant. Thus, it allows for performing a thermo-economic analysis of the plant checking the influence of the main plant design parameters. The focal objective is to analyze the importance on the levelized cost of electricity (LCoE) of the key plant design parameters. The direct influence of parameters from the heliostat field and receiver (as tower height, distance to the first row of heliostats, heliostats size, receiver size and heat losses, etc.) on final LCoE is surveyed. Similarly, parameters from the turbine as pressure ratio, turbine inlet temperature, influence of recuperation and others, are also analyzed. The dimensions of the plant are taken from SOLUGAS prototype near Seville, Spain, although another location with quite different solar conditions in Spain is also considered. LCoE values predicted are about 158 USD/MWh. The analysis concludes that among several parameters surveyed, two of them are key in LCoE predicted values: turbine inlet temperature and solar receiver aperture size.es_ES
dc.description.sponsorshipJunta de Castilla y León of Spain (project SA017P17)es_ES
dc.format.mimetypeapplication/pdf
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectThermo-solar hybrid power plants
dc.subjectOverall plant model
dc.subjectThermo-economic analysis
dc.subjectSensitivity of levelized cost of electricity
dc.subjectSubsystems integration
dc.titleThermo-economic and sensitivity analysis of a central tower hybrid Brayton solar power plantes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.1016/j.applthermaleng.2020.116454
dc.subject.unesco2213 Termodinámica
dc.identifier.doi10.1016/j.applthermaleng.2020.116454
dc.relation.projectIDSA017P17)es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.journal.titleApplied Thermal Engineeringes_ES
dc.volume.number186es_ES
dc.page.initial116454es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional