• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
  • Entre em contato
  • Deixe sua opinião
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.
    Gredos. Repositorio documental de la Universidad de SalamancaUniversidad de Salamanca
    Consorcio BUCLE Recolector

    Navegar

    Todo o repositórioComunidades e ColeçõesPor data do documentoAutoresAssuntosTítulosEsta coleçãoPor data do documentoAutoresAssuntosTítulos

    Minha conta

    EntrarCadastro

    Estatísticas

    Ver as estatísticas de uso
    Estadísticas totales de uso y lectura

    ENLACES Y ACCESOS

    Derechos de autorPolíticasGuías de autoarchivoFAQAdhesión USAL a la Declaración de BerlínProtocolo de depósito, modificación y retirada de documentos y datosSolicitud de depósito, modificación y retirada de documentos y datos

    COMPARTIR

    Ver item 
    •   Página inicial
    • Repositório Científico
    • Publicaciones periódicas EUSAL
    • Revista ORL
    • Untitled
    • ORL, Vol.12, n.4
    • Ver item
    •   Página inicial
    • Repositório Científico
    • Publicaciones periódicas EUSAL
    • Revista ORL
    • Untitled
    • ORL, Vol.12, n.4
    • Ver item

    Compartir

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Título
    Nuevas técnicas de Medicina Nuclear en la cirugía del hiperparatiroidismo
    Otros títulos
    New Nuclear Medicine techniques in hyperparathyroidism surgery
    Autor(es)
    García Talavera San Miguel, PalomaAutoridad USAL ORCID
    Díaz González, Luis Gonzaga
    Gómez Caminero, Felipe
    Martín Gómez, Enrique
    Cañadas Salazar, José Cristóbal
    Tamayo Alonso, María PilarAutoridad USAL ORCID
    Palabras clave
    Radioguided surgery
    Hyperparathyroidism
    Hand-held gammacamera
    125I seeds
    ROLL with 99mTc-MAA
    Choline PET-CT
    Hiperparatiroidismo
    Cirugía radioguiada
    Gammacámara portátil
    Semillas de 125I
    PET-CT con colina
    Fecha de publicación
    2021-11-09
    Editor
    Ediciones Universidad de Salamanca (España)
    Citación
    Revista ORL, 12 (2021)
    Resumen
    [EN]Introduction and objective:Radioguided surgery of hyperparathyroidism (HPT) has substantially evolved in recent years, due to the development of new intraoperative tools and the improvement of pre-operative techniques. The aim of this work is to perform a review of the role of choline PET-CT as a preoperative technique, as well as of the use of intraoperative tools, in the radioguided localization of parathyroid adenomas.Synthesis:Choline PET-CT is a pre-operative technique, alternative to the 99mTc-MIBI scintigraphy, for the pre-operative localization of HPT in cases where convencional techniques give negative or doubtful results. This technique has showed good results in two recently published meta-analysis. The radioguided localization by means of gamma probe is still the intraoperative technique of choice in cases where parathyroid glands show significant 99mTc-MIBI uptake. Hand-held gammacamera is an adjuvant tool to the probe, which allows performing an intraoperative imagine and ensuring the complete resection of the specimens. Free hand SPECT is already applied in parathyroid radioguided surgery, but its use is still not widespread, probably because the superiority of this technique over the probe and hand-held gammacamera has not been demonstrated. Radioguided occult lesion localization (ROLL) by means of 99mTc-MAA injection and 125I seed implantation are two successfully used alternatives for the radioguided localization of negative99mTc –MIBI parathyroid glands. Hybrid tracers are being used in the radioguided surgery of the sentinel node, but have not been applied yet in hyperparathyroidism. Conclusions: Choline PET-CT is an increasingly used tool in preoperative HPT localization. Although gammadetector probe remains of choice in HPT surgery —both for its good results at low cost and for the great accumulated experience—; the combined use of the hand-held gammaprobe could be helpful for particular cases as well as to ensure the total excision of the specimens. On the other hand, the injection of 125I seeds and 99mTc-MAA, guided by means of sonography, are useful in 99mTc- MIBI negative cases. Lastly, more experience is required on the application of free hand SPECT and hybrid tracers to HPT surgery on order to demonstrate their possible advantages compared to other widespread tools.
     
    [ES]Introducción y objetivo:/nLa cirugía radioguiada del hiperparatiroidismo (HPT) ha evolucionado en los últimos años, gracias a la aparición de nuevas herramientas intraoperatorias y al perfeccionamiento de las técnicas pre-operatorias. El objetivo de este trabajo es realizar una revisión actualizada del papel del PET-CT con colina como técnica preoperatoria, así como de las herramientas intraoperatorias, en la radiolocalización de adenomas de paratiroides. Síntesis: El PET-CT con colina es una técnica preoperatoria, alternativa a la gammagrafía con 99mTc-MIBI, para la localización pre-quirúrgica del HPT, en casos en que las pruebas convencionales sean negativas o dudosas. Esta técnica ha demostrado buenos resultados en dos metaanálisis publicados recientemente. La localización radioguiada mediante sonda gamma continúa siendo la técnica intraoperatoria de elección en los casos con glándulas paratiroides que muestran captación significativa de 99mTc-MIBI. La gammacámara portátil es una herramienta adyuvante a la sonda, que permite realizar una imagen intraoperatoria y asegurar la completa resección de los especímenes. El "free hand SPECT" ya se está aplicando en la cirugía radioguiada de paratiroides, pero aún su uso no está extendido, probablemente debido a que no se ha demostrado la superioridad de esta técnica frente al uso de la sonda y la gammacámara portátil. La radiolocalización de lesiones ocultas (ROLL) mediante inyección de 99mTc-MAA y la inyección de semillas de 125I son dos alternativas para la localización radioguiada de paratiroides 99mTc-MIBI negativas, y ya están siendo empleadas con éxito. Los trazadores híbridos, empleados ya en la cirugía radioguiada del ganglio centinela, aún no se han aplicado en el hiperparatiroidismo. Conclusiones: El PET-CT con colina es una herramienta exitosa y cada vez más utilizada en la localización pre-operatoria del HPT. Aunque la sonda gammadetectora sigue siendo de elección en la cirugía del HPT, tanto por sus buenos resultados, como por la gran experiencia acumulada y bajo coste; la adición de la gammacámara portátil podría ser de ayuda en casos concretos y para asegurar la exéresis completa de los especímenes. La inyección de semillas con 125I y de 99mTc-MAA, guiada por ecografía, es de utilidad en casos 99mTc-MIBI negativos. La "free hand SPECT" y los trazadores híbridos aún requieren más experiencia en su aplicación a la cirugía del HPT para demostrar sus posibles ventajas frente al resto de herramientas utilizadas.
    URI
    https://hdl.handle.net/10366/148897
    ISSN
    2444-7986
    Aparece en las colecciones
    • ORL, Vol.12, n.4 [13]
    Mostrar registro completo
    Arquivos deste item
    Nombre:
    Nuevas_tecnicas_de_Medicina_Nuclear_en_l.pdf
    Tamaño:
    587.6Kb
    Formato:
    Adobe PDF
    Thumbnail
    Visualizar/Abrir
     
    Universidad de Salamanca
    AVISO LEGAL Y POLÍTICA DE PRIVACIDAD
    2024 © UNIVERSIDAD DE SALAMANCA
     
    Universidad de Salamanca
    AVISO LEGAL Y POLÍTICA DE PRIVACIDAD
    2024 © UNIVERSIDAD DE SALAMANCA