Zur Kurzanzeige

dc.contributor.authorMartín Nieto, Ignacio 
dc.contributor.authorFarfán Martín, Arturo Rafael 
dc.contributor.authorSáez Blázquez, Cristina 
dc.contributor.authorGonzález Aguilera, Diego 
dc.contributor.authorCarrasco García, Pedro 
dc.contributor.authorFarfán Vasco, Emilio
dc.contributor.authorCarrasco García, Javier
dc.date.accessioned2022-05-24T09:27:08Z
dc.date.available2022-05-24T09:27:08Z
dc.date.issued2019
dc.identifier.citationMartín Nieto, E., et al... (2019). Use of 3D electrical resistivity tomography to improve the design of low enthalpy geothermal systems. Geothermics, 79, pp. 1-13.es_ES
dc.identifier.issn0375-6505
dc.identifier.urihttp://hdl.handle.net/10366/149826
dc.description.abstract[EN] In designing low enthalpy geothermal systems, the ideal location and length of the boreholes in the well-field is the key to improve the performance and reduce the costs of the installation. The correct assessment of the heat conductivity of the ground (λ) plays also a very important role in estimating the amount of energy that we are going to be able to obtain from the subsoil and the ideal pace of the process. In low enthalpy geothermal installations based on granite type environments is especially important to improve the information we have from the subsoil at a small scale. This is due to the great horizontal variation we can find on this kind of terrain. Electrical conductivity (C = 1/ρ, ρ = resistivity in ohm meters) can be related to thermal conductivity (λ) of many rock types (Directive (EU), 2019) (see Robertson, 1988). We show that a 3D electrical resistivity survey can be used as a proxy for λ in terrain with weathered and solid granitic rock. Knowledge of λ is essential for the design of efficient ground source heat pump systems that use vertical wells for closed-loop systems. Shorter well lengths are accomplished if wells are in solid granite with high λ. Furthermore the electrical resistivity survey identifies low density, clayey subsurface materials that may require specialized drilling methods. Project cost savings can result from shorter borehole lengths, number of holes, and correct drilling methods.es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectElectrical resistivityes_ES
dc.subjectThermal conductivityes_ES
dc.subjectGranite type rocks (adamellites)es_ES
dc.subjectDesign of the well fieldes_ES
dc.titleUse of 3D electrical resistivity tomography to improve the design of low enthalpy geothermal systemses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.1016/j.geothermics.2019.01.007es_ES
dc.subject.unesco2511.07 Ingeniería de Sueloses_ES
dc.identifier.doi10.1016/j.geothermics.2019.01.007
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.journal.titleGeothermicses_ES
dc.volume.number79es_ES
dc.page.initial1es_ES
dc.page.final13es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Dateien zu dieser Ressource

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Solange nicht anders angezeigt, wird die Lizenz wie folgt beschrieben: Attribution-NonCommercial-NoDerivatives 4.0 Internacional