Show simple item record

dc.contributor.authorGonzález Gil, Diego 
dc.contributor.authorDib Zaitun, Ibrahim 
dc.contributor.authorFlores Fraile, Javier 
dc.contributor.authorLópez Marcos, Joaquín Francisco 
dc.date.accessioned2024-01-24T13:45:03Z
dc.date.available2024-01-24T13:45:03Z
dc.date.issued2022-11
dc.identifier.citationGonzález-Gil, D., Dib-Zaitun, I., Flores-Fraile, J., & López-Marcos, J. (2022). Active Tactile Sensibility in Implant Prosthesis vs. Complete Dentures: A Psychophysical Study. Journal of clinical medicine, 11(22), 6819. https://doi.org/10.3390/jcm11226819es_ES
dc.identifier.urihttp://hdl.handle.net/10366/154630
dc.description.abstract[EN] Background and Objectives: Proprioceptive information from natural dentition and adjacent oral tissues enables correct masticatory function, avoiding damage to the teeth. Periodontium is the main source of this relevant information, and when a tooth is lost, all this proprioceptive sensibility relies on receptors from muscles, the mucous membrane or the temporomandibular joint, and this sensibility gets worse. Active tactile sensibility measures this proprioceptive capability in microns by psychophysical studies consisting of introducing thin metal foils between patients’ dental arches during chewing to see if they are able to notice them or not. Osseoperception is a complex phenomenon that seems to improve this sensibility in patients wearing dental implants. The objective of this investigation is to measure this sensibility in different prosthetic situations by performing a psychophysical investigation. Material and Methods: We divided 67 patients in three groups depending on their prosthetic situation and performed a psychophysical study by introducing aluminium foils of different thicknesses in order to establish an active tactile sensibility threshold in every group. We also measured variables such as prosthetic wearing time, age or gender to see how they may influence threshold values. We used Student’s t-test and Mann–Whitney U tests to analyse these results. Results: Active tactile sensibility threshold values in implants are lower than those from complete dentures but higher than values in natural dentition. However, values in implants are closer to natural dentition than complete denture values. Age, gender or prosthetic wearing time have no influence in active tactile sensibility thresholds. Conclusion: Active tactile sensibility threshold values depend on prosthetic rehabilitations and the mechanoreceptors involved in every situation. Implant prosthesis presents an increased active tactile sensibility thanks to osseoperception phenomenon.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectOsseoperceptiones_ES
dc.subjectTactile sensibilityes_ES
dc.subjectInterocclusal thicknesses_ES
dc.subjectInterocclusal perceptiones_ES
dc.subject.meshDental Prosthesis, Implant-Supported *
dc.titleActive tactile sensibility in implant prosthesis vs. complete dentures: A psychophysical studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.3390/jcm11226819es_ES
dc.subject.unesco3201 Ciencias Clínicases_ES
dc.subject.unescoOdontologíaes_ES
dc.identifier.doi10.3390/jcm11226819
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.essn2077-0383
dc.journal.titleJournal of Clinical Medicinees_ES
dc.volume.number11es_ES
dc.issue.number22es_ES
dc.page.initial6819es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES
dc.subject.decsprótesis dental con soporte por implante *


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional