Mostrar el registro sencillo del ítem

dc.contributor.authorDib Zaitun, Ibrahim 
dc.contributor.authorGuadilla González, Yasmina 
dc.contributor.authorFlores Fraile, Javier 
dc.contributor.authorDib Zakkour, Juan
dc.contributor.authorBenito Garzón, Lorena 
dc.contributor.authorMontero Martín, Javier 
dc.date.accessioned2024-01-30T20:51:50Z
dc.date.available2024-01-30T20:51:50Z
dc.date.issued2022-06-22
dc.identifier.citationDib-Zaitum I, Guadilla-González Y, Flores-Fraile J, Dib-Zakkour J, Benito-Garzón L, Montero J. Effect Morphology and Surface Treatment of the Abutments of Dental Implants on the Dimension and Health of Peri-Implant Biological Space. Materials (Basel). 2022;15(13):4422. https://doi.org/10.3390/ma15134422. Published 2022 Jun 22es_ES
dc.identifier.urihttp://hdl.handle.net/10366/155052
dc.description.abstract[ES]La configuración gingival alrededor de los pilares de los implantes es de suma importancia para preservar el hueso marginal subyacente y, por tanto, para el éxito a largo plazo de los implantes dentales. El objetivo del trabajo fue estudiar, clínica e histológicamente, los efectos producidos por el cambio en la morfología y tratamiento superficial de los pilares conectados a los implantes endoóseos. En particular, el objetivo fue conocer el efecto del cambio de forma del pilar transepitelial y el tratamiento de su superficie sobre las dimensiones, calidad y salud de los componentes del espacio biológico periimplantario, como las dimensiones del epitelio y tejidos conectivos del espacio biológico, la concentración de células inflamatorias y la densidad de fibras de colágeno. Se realizó un ensayo clínico de 10 pacientes con maxilar totalmente edéntulo, a quienes se les insertaron cuatro implantes (IPX4010_GALIMPLANT®, Sarria, España) en la zona del primer y segundo molar en ambos lados con cirugía de implantes guiada por computadora, con el el objetivo final de evaluar la calidad de la unión del tejido blando periimplantario alrededor de los pilares transepiteliales empleados (mecanizado estético (RM), anodizado estético (RA), mecanizado estrecho (SM) y anodizado estrecho (SA)). A las 8 semanas se recogieron las muestras (retirada del conjunto implante-pilar con su tejido duro y blando circundante) y se procesaron para su posterior análisis histológico e histomorfométrico con el fin de estudiar las dimensiones anteriormente mencionadas de acuerdo a los objetivos del estudio. El análisis estadístico de los resultados reveló que los pilares estrechos mecanizados tienen un mejor desempeño considerando las variables analizadas con alturas epitelial y conectiva de 1,52 mm y 2,3 mm, respectivamente. La densidad conectiva (densidad de las fibras de colágeno) fue alta en el 85,7% coincidiendo con los pilares estrechos, y de ellos el 92,9% se asoció al tratamiento superficial de la superficie mecanizada. Todas las variables estudiadas, a pesar del pequeño tamaño de la muestra, mostraron la superioridad del pilar mecanizado estrecho entre los cuatro grupos.es_ES
dc.description.abstract[EN]Statement of the problem: The gingival configuration around implant abutments is of paramount importance for preserving the underlying marginal bone, and hence for the long-term success of dental implants. Objective: The objective was to study, clinically and histologically, the effects of the change in the morphology of abutments connected to the endosseous implant, and of their surface treatment. In particular, the objective was to ascertain the effect of changing the shape of the transepithelial pillar and the treatment of its surface on the dimensions, quality and health of the components of the peri-implant biological space, such as the dimensions of the epithelial and connective tissues of the biological space, the concentration of inflammatory cells and the density of collagen fibers. Methods: A clinical trial of 10 patients with a totally edentulous maxilla, who had four implants (IPX4010_GALIMPLANT®, Sarria, Spain) inserted in the area of the first and second molars on both sides with computer-guided implant surgery, was conducted with the final purpose of assessing the quality of the peri-implant soft tissue attachment around the transepithelial abutments which were employed (aesthetic machined (RM), aesthetic anodized (RA), slim machined (SM) and slim anodized (SA)). At 8 weeks and following the collection of the samples (removal of the implant-abutment assembly with its surrounding hard and soft tissue) and their processing for subsequent histological and histomorphometric analysis in order to study the dimensions, quality and health of the peri-implant soft tissue area, the variables previously mentioned were determined according to the aims of the study. By using appropriate diameter trephine in order to obtain a useful fringe of soft tissue around the transepithelial pillars, ANOVA and chi-square tests were performed. Results: The SPSS statistical analysis ANOVA results revealed that the machined slim abutments have a better performance considering the variables analyzed with epithelial and connective attachment heights of 1.52 mm and 2.3 mm, respectively, and that connective density (density of collagen fibers) was high at 85.7% of the sample size affected by the design for the slim abutments and 92.9% of the high-density sample size affected by the surface treatment for the machined surface. Conclusions: All variables studied, despite the small sample size, showed the superiority of the slim machined abutment among the four groups.en_EN
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.subjectPeri-implantitises_ES
dc.subjectTitanium surface treatmentes_ES
dc.subjectDental Abutmentses_ES
dc.subject.meshDental Implants *
dc.subject.meshPeri-Implantitis *
dc.subject.meshDental Abutments *
dc.titleEffect morphology and surface treatment of the abutments of dental implants on the dimension and health of peri-implant biological spacees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.3390/ma15134422es_ES
dc.identifier.doi10.3390/MA15134422
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.essn1996-1944
dc.journal.titleMaterialses_ES
dc.volume.number15es_ES
dc.issue.number13es_ES
dc.page.initial4422es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES
dc.subject.decspilares dentales *
dc.subject.decsimplantes dentales *
dc.subject.decsperiimplantitis *