Show simple item record

dc.contributor.authorBlaya Haro, Fernando
dc.contributor.authorde Agustín Del Burgo, José María
dc.contributor.authorD’Amato, Roberto
dc.contributor.authorIslán, Manuel E.
dc.contributor.authorSoriano Heras, Enrique
dc.contributor.authorGarcía Alonso, Jesús Manuel
dc.contributor.authorJuanes Méndez, Juan Antonio 
dc.date.accessioned2024-05-17T08:24:05Z
dc.date.available2024-05-17T08:24:05Z
dc.date.issued2019
dc.identifier.citationHaro, F. B., de Agustín del Burgo, J. M., D’Amato, R., Islán, M., Heras, E. S., Alonso, J. M. G., & Mendez, J. A. J. (2019). Monitoring an Analysis of Perturbations in Fusion Deposition Modelling (FDM) Processes for the Use of Biomaterials. Journal of Medical Systems, 43(5). https://doi.org/10.1007/S10916-019-1236-2es_ES
dc.identifier.issn0148-5598
dc.identifier.urihttp://hdl.handle.net/10366/157917
dc.description.abstract[EN]During an FDM production process, there are different external disturbances to the characteristics of the machine that can affect to the production process. These disturbances will cause the final result differs from the desired one. Moreover, these disturbances, such as temperature or chamber humidity, are extremely important in case of using biocompatible materials. The use of these kind of materials with not controlled environment, can cause them to modify or loss of their properties; what will make the product unusable. Apart from these external disturbances, the conditions of the machine to which the material is subjected must also be considered, such as temperature, vibrations or extrusion speed. The monitoring of all these data will allow to know the conditions to which the product was exposed during the process. In this way, it will be able to verify the validity of the final product. For these reasons, the purpose of this work is to monitor the conditions of production of structures with biocompatible materials by fused deposition modelling (FDM) technique. This monitoring will allow us to obtain a report that guarantee the technical and geometrical characteristics of the model and the biomaterial properties. The parameters chosen to be monitored are: Diameter of filament use, temperature in extrusion nozzle, ambient temperature in closed chamber, ambient humidity in closed chamber. The obtained results, after collected and analysing the data, present variations of up to 3% in the temperature of the nozzle of the extruder with respect to set temperature. In the case of the filament diameter the difference with respect to the value provided from the filament supplier is of 13,7%. In addition, the results show how the ambient humidity in closed chamber has changed by 2 percentage points and the ambient temperature in closed chamber has been increased 6,52 °C with respect to the set values.es_ES
dc.language.isoenges_ES
dc.publisherSpringeres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectAdditive manufacturing processes_ES
dc.subjectBiomaterialses_ES
dc.subjectSensores_ES
dc.subjectMedical applicationes_ES
dc.titleMonitoring an analysis of perturbations in Fusion Deposition Modelling (FDM) processes for the use of biomaterialses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://link.springer.com/article/10.1007/s10916-019-1236-2es_ES
dc.subject.unesco2410.02 Anatomía Humanaes_ES
dc.identifier.doi10.1007/s10916-019-1236-2
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.essn1573-689X
dc.journal.titleJournal of Medical Systemses_ES
dc.volume.number43es_ES
dc.issue.number5es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional