Mostrar el registro sencillo del ítem

dc.contributor.authorJiménez Candil, Francisco Javier 
dc.contributor.authorArenal, Ángel
dc.contributor.authorGarcía-Alberola, Arcadio
dc.contributor.authorOrtíz, Mercedes
dc.contributor.authordel Castillo, Silvia
dc.contributor.authorFernández-Portales, Javier
dc.contributor.authorSánchez-Muñoz, Juan
dc.contributor.authorMartínez-Sánchez, Juan
dc.contributor.authorGonzález-Torrecilla, Esteban
dc.contributor.authorAtienza, Felipe
dc.contributor.authorPuchol, Alberto
dc.contributor.authorAlmendral, Jesús
dc.date.accessioned2024-12-05T15:34:40Z
dc.date.available2024-12-05T15:34:40Z
dc.date.issued2005-02-01
dc.identifier.citationJiménez-Candil, J., Arenal, A., García-Alberola, A., Ortiz, M., Del Castillo, S., Fernández-Portales, J., Sánchez-Muñoz, J., Martínez-Sánchez, J., González-Torrecilla, E., Atienza, F., Puchol, A., & Almendral, J. (2005). Fast ventricular tachycardias in patients with implantable cardioverter-defibrillators: Efficacy and safety of antitachycardia pacing - A prospective and randomized study. Journal of the American College of Cardiology (Vol. 45, Número 3, pp. 460-461). https://doi.org/10.1016/J.JACC.2004.11.008es_ES
dc.identifier.issn0735-1097
dc.identifier.urihttp://hdl.handle.net/10366/160973
dc.description.abstract[EN]In this prospective, multicenter, randomized study of 137 patients with ICDs, the programming of antitachycardia pacing therapy (ATP) consisting of a burst of 5 pulses at 84% of the tachycardia cycle length (CL) reduced by 84% the incidence of shocks to treat fast ventricular tachycardias (FVT), defined by a CL between 240-310 ms. The strategy based on ATP programming was associated with a reduction in episode duration (9.3 s ± 8.4 vs 14.8 ± 4.6 s; p<0.05) and the incidence of syncope/near-syncope due to FVT (3.7% vs. 54%; p<0.001). Beta- blocker therapy was associated with an increased ATP efficacy.
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsCC0 1.0 Universal*
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.subjectAntitachycardia pacinges_ES
dc.subjectImplantable cardioverter-defibrillatores_ES
dc.subject.meshAged *
dc.subject.meshProspective Studies *
dc.subject.meshTreatment Outcome *
dc.subject.meshHumans *
dc.subject.meshDefibrillators *
dc.subject.meshMiddle Aged *
dc.subject.meshTachycardia *
dc.titleFast ventricular tachycardias in patients with implantable cardioverter-defibrillators: Efficacy and safety of antitachycardia pacing - A prospective and randomized studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://www.jacc.org/doi/10.1016/j.jacc.2004.11.008es_ES
dc.identifier.doi10.1016/j.jacc.2004.11.008
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.pmid15680729
dc.identifier.essn1558-3597
dc.journal.titleJournal of the American College of Cardiologyes_ES
dc.volume.number45es_ES
dc.issue.number3es_ES
dc.page.initial460es_ES
dc.page.final461es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES
dc.subject.decsdesfibriladores *
dc.subject.decsresultado del tratamiento *
dc.subject.decshumanos *
dc.subject.decsanciano *
dc.subject.decsmediana edad *
dc.subject.decstaquicardia *
dc.subject.decsestudios prospectivos *


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

CC0 1.0 Universal
Excepto si se señala otra cosa, la licencia del ítem se describe como CC0 1.0 Universal