Zur Kurzanzeige

dc.contributor.authorSala Hernandez, Angela
dc.contributor.authorFrasson, Matteo
dc.contributor.authorGarcía‐Granero, Alvaro
dc.contributor.authorHervás Marín, David
dc.contributor.authorLaiz Marro, Begoña
dc.contributor.authorAlonso Pardo, Ricardo
dc.contributor.authorAldrey Cao, Inés
dc.contributor.authorAlvarez Perez, José Antonio
dc.contributor.authorRoque Castellano, Cristina
dc.contributor.authorGarcía González, Jose María
dc.contributor.authorTabet Almeida, Janine
dc.contributor.authorGarcía‐Granero, Eduardo
dc.contributor.authorAlcázar Montero, José Antonio 
dc.contributor.authorEDEN Study Group
dc.date.accessioned2024-12-10T11:30:42Z
dc.date.available2024-12-10T11:30:42Z
dc.date.issued2021
dc.identifier.citationSala Hernandez, A., Frasson, M., García‐Granero, A., Hervás Marín, D., Laiz Marro, B., Alonso Pardo, R., Aldrey Cao, I., Alvarez Perez, J. A., Roque Castellano, C., García González, J. M., Tabet Almeida, J., García‐Granero, E., y the EDEN study group. (2021). Diagnostic accuracy of C‐reactive protein, procalcitonin and neutrophils for the early detection of anastomotic leakage after colorectal resection: A multicentric, prospective study. Colorectal Disease, 23(10), 2723-2730. https://doi.org/10.1111/codi.15845es_ES
dc.identifier.issn1462-8910
dc.identifier.urihttp://hdl.handle.net/10366/160996
dc.description.abstract[EN]Aim: The aim was to determine the accuracy of C-reactive protein (CRP), procalcitonin and neutrophils in the early detection (fourth postoperative day) of anastomotic leakage (AL) after colorectal surgery. Methods: We conducted a multicentre, prospective study that included a consecutive series of patients who underwent colorectal resection with anastomosis without ostomy (September 2015 to December 2017). CRP, procalcitonin and neutrophil values on the fourth postoperative day after colorectal resection along with the postoperative outcome (60-day AL, morbidity and mortality) were prospectively included in an online, anonymous database. Results: The analysis ultimately included 2501 cases. The overall morbidity and mortality was 30.1% and 1.6%, respectively, and the AL rate was 8.6%. The area under the receiver operating characteristic curve values (95% CI) for detecting AL were 0.84 (0.81–0.87), 0.75 (0.72–0.79) and 0.70 (0.66–0.74) for CRP, procalcitonin and neutrophils, respectively. The best cut-off level for CRP was 119 mg/l, resulting in 70% sensitivity, 81% specificity and 97% negative predictive value. After laparoscopic resection, the accuracy for CRP and procalcitonin was increased, compared with open resection. The combination of two or three of these biomarkers did not significantly increase their accuracy. Conclusion: On the fourth postoperative day, CRP was the most reliable marker for excluding AL. Its high negative predictive value, especially after laparoscopic resection, allows for safe hospital discharge on the fourth postoperative day. The routine use of procalcitonin or neutrophil counts does not seem to increase the diagnostic accuracy.es_ES
dc.language.isoenges_ES
dc.publisherWileyes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectAnastomotic leakagees_ES
dc.subjectBiomarkerses_ES
dc.subjectColorectal surgeryes_ES
dc.subjectC-reactive proteines_ES
dc.subjectNeutrophilses_ES
dc.subjectProcalcitonines_ES
dc.subject.meshAnastomosis, Surgical *
dc.subject.meshColorectal Surgery *
dc.subject.meshNeutrophils *
dc.subject.meshC-Reactive Protein *
dc.subject.meshBiomarkers, Pharmacological *
dc.titleDiagnostic accuracy of C‐reactive protein, procalcitonin and neutrophils for the early detection of anastomotic leakage after colorectal resection: a multicentric, prospective studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.1111/codi.15845es_ES
dc.subject.unesco3207.13 Oncologíaes_ES
dc.subject.unesco2407.04 Citologíaes_ES
dc.identifier.doi10.1111/codi.15845
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.essn1463-1318
dc.journal.titleColorectal Diseasees_ES
dc.volume.number23es_ES
dc.issue.number10es_ES
dc.page.initial2723es_ES
dc.page.final2730es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES
dc.subject.decscirugía colorrectal *
dc.subject.decsbiomarcadores farmacológicos *
dc.subject.decsproteína C reactiva *
dc.subject.decsneutrófilos *
dc.subject.decsanastomosis quirúrgica *


Dateien zu dieser Ressource

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige

Atribución 4.0 Internacional
Solange nicht anders angezeigt, wird die Lizenz wie folgt beschrieben: Atribución 4.0 Internacional