Afficher la notice abrégée

dc.contributor.advisorFonseca, Patriciaes_ES
dc.contributor.advisorMontero Martín, Javier es_ES
dc.contributor.advisorCorreia, Andrées_ES
dc.contributor.authorMartins Quezada, Margarida
dc.date.accessioned2024-12-11T12:38:42Z
dc.date.available2024-12-11T12:38:42Z
dc.date.issued2024
dc.identifier.urihttp://hdl.handle.net/10366/161065
dc.description.abstract[SPA]La rugosidad de la superficie es un parámetro clínico crucial porque impacta directa o indirectamente en la acumulación de placa microbiana en los tejidos que están en contacto con los materiales dentales. Esta investigación subraya la necesidad de integrar el perfil primario (P) en el análisis de la superficie. El perfil primario es esencial para evaluar la rugosidad de la superficie, ya que representa las características detalladas de la superficie, incluidos picos, valles y todas las variaciones de altura. Además, parámetros específicos de altura como la asimetría (Psk) y la curtosis (Pku) son importantes para diferenciar superficies con formas variadas que pueden compartir valores idénticos de Pa, proporcionando así una comprensión más profunda de la distribución de las alturas en la superficie. En esta investigación, las resinas CAD/CAM mostraron valores más bajos de rugosidad superficial (Pa), mientras que las resinas termopolimerizables demostraron una consistencia superior en sus perfiles de superficie. Como se discutió anteriormente, factores intrínsecos como la temperatura de polimerización, la presión y la composición del polimetilmetacrilato (PMMA) afectan significativamente la topografía de la superficie y dictan la elección del procedimiento de pulido. Seleccionar la técnica de pulido adecuada es esencial para mejorar el atractivo estético, minimizar la retención de placa bacteriana y aumentar la resistencia a los fluidos orales. Los protocolos de pulido influyen significativamente en la rugosidad de la superficie de los materiales de base de prótesis al eliminar sistemáticamente las capas rugosas de la superficie. Tanto las técnicas de pulido mecanizadas como las convencionales afectan la topografía superficial de las resinas acrílicas. El protocolo mecanizado proporciona consistentemente valores uniformes de asimetría y curtosis, mientras que el método convencional muestra una variabilidad notable en los valores de Pa obtenidoses_ES
dc.description.abstract[ENG]Surface roughness is a critical clinical factor because it influences the retention of microbial plaque on tissues in contact with denture base resins. This research emphasizes the importance of incorporating the primary profile (P) in surface analysis. The primary profile is crucial to evaluate surface roughness as it represents detailed surface characteristics, including peaks, valleys and all variations in height. Furthermore, specific height parameters like skewness (Psk) and kurtosis (Pku) are important for differentiate surfaces with varying shapes that may present identical Pa values, thereby providing deeper insights into the height distribution across the surface. In our research, CAD/CAM resins showed lower surface roughness values (Pa), whereas heat-cured resins demonstrated superior consistency in their surface profiles. Intrinsic factors such as polymerization temperature, pressure and composition of poly (methyl methacrylate) (PMMA) significantly affect surface topography and dictate the choice of polishing procedure. Polishing protocols significantly influence the surface roughness of denture base materials by systematically removing rough layers from the surface. Both mechanized and conventional polishing techniques affect surface topography of acrylic resins. The mechanized protocol consistency delivers uniform skewness and kurtosis values, while conventional method exhibits notable variability in Pa values obtained.
dc.language.isoenges_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectTesis y disertaciones académicases_ES
dc.subjectUniversidad de Salamanca (España)es_ES
dc.subjectTesis Doctorales_ES
dc.subjectAcademic dissertationses_ES
dc.subjectResinas acrílicases_ES
dc.subjectOdontologíaes_ES
dc.subjectRugosidad superficiales_ES
dc.subjectDiseño asistido por ordenadores_ES
dc.subject.meshComputer-Aided Design *
dc.subject.meshAcrylic Resins *
dc.subject.meshDentistry *
dc.subject.meshOral Surgical Procedures *
dc.titleEvaluation of surface roughness height parameters in acrylic resins for prosthetic baseses_ES
dc.title.alternativeEvaluación de parámetros de altura de rugosidad superficial en resinas acrílicas para bases protéticases_ES
dc.typeinfo:eu-repo/semantics/doctoralThesises_ES
dc.subject.unesco3213.13 Ortodoncia-Estomatologíaes_ES
dc.subject.unesco3311.03 Instrumentos Para Odontologíaes_ES
dc.subject.unesco3213.04 Cirugía de Huesoses_ES
dc.subject.unesco1203.09 Diseño Con Ayuda del Ordenadores_ES
dc.identifier.doi10.14201/gredos.161065
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.subject.decsodontología *
dc.subject.decsdiseño asistido por ordenador *
dc.subject.decsprocedimientos quirúrgicos orales *
dc.subject.decsresinas acrílicas *


Fichier(s) constituant ce document

Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Attribution-NonCommercial-NoDerivatives 4.0 Internacional