Afficher la notice abrégée

dc.contributor.authorGómez Marcos, Manuel Ángel 
dc.contributor.authorRecio Rodríguez, José Ignacio 
dc.contributor.authorPatino Alonso, María Carmen 
dc.contributor.authorAgudo-Conde, Cristina
dc.contributor.authorGómez Sánchez, Leticia
dc.contributor.authorRodríguez Sánchez, Emiliano 
dc.contributor.authorMartín-Cantera, Carlos
dc.contributor.authorGarcía Ortiz, Luis 
dc.date.accessioned2025-01-24T08:39:41Z
dc.date.available2025-01-24T08:39:41Z
dc.date.issued2011
dc.identifier.citationGómez-Marcos, M. Á., Recio-Rodríguez, J. I., Patino-Alonso, M. C., Agudo-Conde, C., Gómez-Sánchez, L., Rodríguez-Sánchez, E., ... & García-Ortiz, L. (2011). Relationship between intima-media thickness of the common carotid artery and arterial stiffness in subjects with and without type 2 diabetes: a case-series report. Cardiovascular diabetology, 10, 1-8.es_ES
dc.identifier.issn1475-2840
dc.identifier.urihttp://hdl.handle.net/10366/162412
dc.description.abstract[EN]Background We examined the relationship between the intima-media thickness of the common carotid artery (CCA-IMT) and arterial stiffness, assessed by pulse wave velocity (PWV), the ambulatory arterial stiffness index (AASI) and the augmentation index (AIx) in subjects with and without type 2 diabetes. Methods A case-series study was made in 366 patients (105 diabetics and 261-non-diabetics). Ambulatory blood pressure monitoring was performed on a day of standard activity with the SpaceLabs 90207 system. AASI was calculated as "1-slope" from the within-person regression of diastolic-on-systolic ambulatory blood pressure readings. PWV and AIx were measured with the SphygmoCor system, and a Sonosite Micromax ultrasound unit was used for automatic measurements of CCA-IMT. Results PWV, AASI and CCA-IMT were found to be greater in diabetic patients, while no differences in AIx were observed between the two groups. CCA-IMT was independently correlated to the three measures of arterial stiffness in both groups. We found an increase in CCA-IMT of 0.40, 0.24 and 0.36 mm in diabetics, and of 0.48, 0.17 and 0.55 mm in non-diabetics for each unit increase in AASI, AIx and PWV. The variability of CCA-IMT was explained mainly by AASI, AIx and gender in diabetic patients, and by age, gender, AASI and PWV in non-diabetic patients. Conclusions CCA-IMT showed a positive correlation to PWV, AASI and AIx in subjects with and without type 2 diabetes. However, when adjusting for age, gender and heart rate, the association to PWV was lost in diabetic patients, in the same way as the association to Alx in non-diabetic patients. The present study demonstrates that the three measures taken to assess arterial stiffness in clinical practice are not interchangeable, nor do they behave equally in all subjects.es_ES
dc.description.sponsorshipThis project was supported by the Regional Health Management of Castilla y León (SACYL) in the call of 26 March 2009 and resolved on 7 July 2009 (GRS. 428/A/09), the ISCIII (RD06/018/27) and the FEDER.es_ES
dc.language.isoenges_ES
dc.rightsCC0 1.0 Universal*
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.subjectArterial Stiffnesses_ES
dc.subjectPulse Wave Velocityes_ES
dc.subjectAugmentation Indexes_ES
dc.subjectClinical Blood Pressurees_ES
dc.subjectPulse Wave Analysises_ES
dc.subject.meshBlood Pressure Monitors *
dc.titleRelationship between intima-media thickness of the common carotid artery and arterial stiffness in subjects with and without type 2 diabetes: a case-series reportes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/ 10.1186/1475-2840-10-3es_ES
dc.subject.unescoPulse Wave Analysises_ES
dc.subject.unescoArterial Stiffnesses_ES
dc.subject.unescoAugmentation Indexes_ES
dc.identifier.doi10.1186/1475-2840-10-3
dc.relation.projectIDISCIII (RD06/018/27)es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.journal.titleCardiovascular Diabetologyes_ES
dc.volume.number10es_ES
dc.issue.number1es_ES
dc.page.initial3es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES
dc.subject.decsmonitores de presión arterial *


Fichier(s) constituant ce document

Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

CC0 1.0 Universal
Excepté là où spécifié autrement, la license de ce document est décrite en tant que CC0 1.0 Universal