Mostra i principali dati dell'item

dc.contributor.authorZhang, Yue
dc.contributor.authorJohannesen, Peter Tinggaard 
dc.contributor.authorMolaee Ardekani, Behnam
dc.contributor.authorWijetillake, Aswin
dc.contributor.authorAttili Chiea, Rafael
dc.contributor.authorHasan, Pierre Yves
dc.contributor.authorSegovia Martínez, Manuel
dc.contributor.authorLópez Poveda, Enrique A. 
dc.date.accessioned2025-11-05T08:56:12Z
dc.date.available2025-11-05T08:56:12Z
dc.date.issued2025-01
dc.identifier.citationZhang, Y., Johannesen, P. T., Molaee-Ardekani, B., Wijetillake, A., Attili Chiea, R., Hasan, P.-Y., Segovia-Martínez, M., y Lopez-Poveda, E. A. (2025). Comparison of performance for cochlear-implant listeners using audio processing strategies based on short-time fast fourier transform or spectral feature extraction. Ear & Hearing, 46(1), 163-183. https://doi.org/10.1097/AUD.0000000000001565
dc.identifier.issn0196-0202
dc.identifier.urihttp://hdl.handle.net/10366/167662
dc.description.abstract[EN] Objectives: We compared sound quality and performance for a conventional cochlear-implant (CI) audio processing strategy based on short-time fast-Fourier transform (Crystalis) and an experimental strategy based on spectral feature extraction (SFE). In the latter, the more salient spectral features (acoustic events) were extracted and mapped into the CI stimulation electrodes. We hypothesized that (1) SFE would be superior to Crystalis because it can encode acoustic spectral features without the constraints imposed by the short-time fast-Fourier transform bin width, and (2) the potential benefit of SFE would be greater for CI users who have less neural cross-channel interactions. Design: To examine the first hypothesis, 6 users of Oticon Medical Digisonic SP CIs were tested in a double-blind design with the SFE and Crystalis strategies on various aspects: word recognition in quiet, speech-in-noise reception threshold (SRT), consonant discrimination in quiet, listening effort, melody contour identification (MCI), and subjective sound quality. Word recognition and SRTs were measured on the first and last day of testing (4 to 5 days apart) to assess potential learning and/or acclimatization effects. Other tests were run once between the first and last testing day. Listening effort was assessed by measuring pupil dilation. MCI involved identifying a five-tone contour among five possible contours. Sound quality was assessed subjectively using the multiple stimulus with hidden reference and anchor (MUSHRA) paradigm for sentences, music, and ambient sounds. To examine the second hypothesis, cross-channel interaction was assessed behaviorally using forward masking. Results: Word recognition was similar for the two strategies on the first day of testing and improved for both strategies on the last day of testing, with Crystalis improving significantly more. SRTs were worse with SFE than Crystalis on the first day of testing but became comparable on the last day of testing. Consonant discrimination scores were higher for Crystalis than for the SFE strategy. MCI scores and listening effort were not substantially different across strategies. Subjective sound quality scores were lower for the SFE than for the Crystalis strategy. The difference in performance with SFE and Crystalis was greater for CI users with higher channel interaction. Conclusions: CI-user performance was similar with the SFE and Crystalis strategies. Longer acclimatization times may be required to reveal the full potential of the SFE strategy.es_ES
dc.description.sponsorshipWe thank all our participants for their time. We also thank Dr. Alejandro Soler Valcárcel in Hospital Clínico Universitario Virgen de la Arrixaca for help with patient recruitment.es_ES
dc.language.isoenges_ES
dc.publisherLippincott Williams & Wilkins
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCochlear implantes_ES
dc.subjectDeafnesses_ES
dc.subjectHearinges_ES
dc.subjectPhonetic featurees_ES
dc.subjectSound coding strategyes_ES
dc.subjectSpectral processinges_ES
dc.titleComparison of Performance for Cochlear-Implant Listeners Using Audio Processing Strategies Based on Short-Time Fast Fourier Transform or Spectral Feature Extractiones_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.1097/aud.0000000000001565
dc.subject.unesco3201 Ciencias Clínicas
dc.subject.unesco2411.13 Fisiología de la Audición
dc.subject.unesco3314.01 Órganos Artificiales
dc.identifier.doi10.1097/AUD.0000000000001565
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.essn1538-4667
dc.journal.titleEar & Hearinges_ES
dc.volume.number46es_ES
dc.issue.number1es_ES
dc.page.initial163es_ES
dc.page.final183es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Files in questo item

Thumbnail

Questo item appare nelle seguenti collezioni

Mostra i principali dati dell'item

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional