Show simple item record

dc.contributor.authorAlio Sanz, J.
dc.contributor.authorClaros Stucci, Miguel
dc.contributor.authorAlbaladejo Martínez, Alberto Francisco 
dc.contributor.authorIglesias Conde, Carmen
dc.contributor.authorAlvarado Lorenzo, Alfonso 
dc.date.accessioned2026-01-12T16:42:39Z
dc.date.available2026-01-12T16:42:39Z
dc.date.issued2016-04
dc.identifier.citationAlió-Sanz, J. J., Claros-Stucchi, M., Albaladejo, A., Iglesias-Conde, C., & Alvarado-Lorenzo, A. (2016). In vitro comparative study on the friction of stainless steel wires with and without Orthospeed® (JAL 90458) on an inclined plane. Journal of Clinical and Experimental Dentistry, 8(2), e141-e145. https://doi.org/10.4317/JCED.52715es_ES
dc.identifier.issn1989-5488
dc.identifier.urihttp://hdl.handle.net/10366/168668
dc.description.abstract[EN]During the treatment of orthodontics, in the mechanics of slide, there takes place friction, which they reduce the slide of the arch across bracket. Therefore, clinical there takes place an increase of the time of treatment. There are different the technologies that try to reduce this friction, as the self-ligating braces. The purpose of this study was to research the in vitro behavior of JAL 90458 as a buffering agent which reduces friction between brackets and stainless steel arch wires of different cross sections and sizes. Three types of stainless steel wires with different cross sections and three types of ligatures were used with and without JAL 90458 to measure the friction according to the time and distance traveled by the brackets on an inclined plane with two angulations. The Kruskal-Wallis one-way analysis of variance by ranks was applied to determine the degree of friction between the group using and the group not using the product (P ≤ .05). Separate analysis of the arch wires, ligatures and angulation with and without the compound revealed statistically significant differences between the groups, showing that friction was reduced significantly when JAL 90458 was used (P ≤ .01). The 0.021x0.025" arch wires and the arch wires attached using elastic ligatures produce the least resistance to sliding among all of those analyzed when the product was not used (P ≤ .05). The results show that JAL 90458 reduces friction independently of arch wire cross section, type of ligature and angulation of the measuring instrument.es_ES
dc.language.isoenges_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFricciónes_ES
dc.subjectOrtodonciaes_ES
dc.subject.meshFriction *
dc.subject.meshIn Vitro *
dc.titleIn vitro comparative study on the friction of stainless steel wires with and without Orthospeed® (JAL 90458) on an inclined planees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.4317/JCED.52715es_ES
dc.identifier.doi10.4317/jced.52715
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.pmid27034753
dc.identifier.essn1989-5488
dc.journal.titleJournal of clinical and experimental dentistryes_ES
dc.volume.number8es_ES
dc.issue.number2es_ES
dc.page.initiale141es_ES
dc.page.finale145es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES
dc.subject.decsin vitro *
dc.subject.decsfricción *


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional