| dc.contributor.advisor | Zubizarreta Macho, Álvaro | es_ES |
| dc.contributor.author | Cruz Jiménez, Silvia de la | |
| dc.date.accessioned | 2026-03-10T12:04:00Z | |
| dc.date.available | 2026-03-10T12:04:00Z | |
| dc.date.issued | 2025 | |
| dc.identifier.uri | http://hdl.handle.net/10366/170405 | |
| dc.description | Los resultados de la presente Tesis Doctoral han sido publicados en la siguiente revista de investigación: Cruz-Jiménez S, Martínez-Alcaraz P, Flores-Fraile J, Agustín-Panadero R, Lobo-Galindo AB, Carbonell-López C, Zubizarreta-Macho Á. Evaluating the Impact of Pontic Geometry on Load to Failure and Displace-ment in Implant-Supported Monolithic Zirconia Prostheses: An In Vitro Analysis. J Funct Biomater. 2025 Feb 20;16(3):76. doi: 10.3390/jfb16030076. PMID: 40137355; PMCID: PMC11942727. | es_ES |
| dc.description.abstract | [ES] En las prótesis monoliticas de zirconia atornilladas y soportadas sobre implantes el diseño del póntico puede influir frente a la carga de fractura. Este estudio tuvo como objetivo evaluar cómo afecta el diseño del póntico en la resistencia a la fractura de dichas restauraciones. Se diseñaron cuarenta prótesis mediante soft-ware CAD dental y se dividieron en cuatro grupos (n = 10): (A) pónticos planos y anchos (10 mm de ancho, 8 mm de alto), (B) pónticos cóncavos y anchos (10 mm de ancho, 5,5 mm de alto), (C) pónticos planos y estrechos (6 mm de ancho, 8 mm de alto), y (D) pónticos cóncavos y estrechos (6 mm de ancho, 5,5 mm de alto). Todas las muestras fueron sometidas a ciclos térmicos y mecánicos, y a una carga de fractura mediante flexión en tres puntos. Las cargas máximas de fractura y los desplazamientos se analizaron mediante ANOVA unidireccional. Se observaron diferencias estadísticamente significativas entre los grupos tanto en la carga de fractura (p = 0,001) como en el desplazamiento (p = 0,002). Con los resultados obtenidos se determinó que la geometría del póntico influye de forma significativa en la resistencia a la fractura y el comportamiento frente a la deformación de las prótesis monolíticas de zirconia. | es_ES |
| dc.description.abstract | [EN] The pontic design may influence the load-to-failure performance of fixed implant-supported screw-retained monolithic zirconia prostheses. This study aimed to evaluate the effect of pontic geometry on the fracture resistance of such restorations. Forty restorations were designed using dental CAD software and divided into four groups (n = 10 each): (A) Flat + Wide-pontics with a flat contour, 10 mm in width and 8 mm in height; (B) Concave + Wide-pontics with a concave contour, 10 mm in width and 5,5 mm in height; (C) Flat + Narrow-pontics with a flat contour, 6 mm in width and 8 mm in height; and (D) Concave + Narrow-pontics with a concave contour, 6 mm in width and 5,5 mm in height. All specimens underwent thermal and mechanical cycling, followed by a fracture load test using a three-point bending setup. Maximum fracture loads and displacements were analyzed using one-way ANOVA. Statistically significant differences were observed among the groups for both load to failure (p = 0.001) and displacement (p = 0.002). These findings indicate that pontic geometry significantly influences the fracture resistance and deformation behavior of monolithic zirconia prostheses. | |
| dc.language.iso | spa | es_ES |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.subject | Tesis y disertaciones académicas | es_ES |
| dc.subject | Universidad de Salamanca (España) | es_ES |
| dc.subject | Tesis Doctoral | es_ES |
| dc.subject | Academic dissertations | es_ES |
| dc.subject | Zirconia monolítica | es_ES |
| dc.subject | Diseño del póntico | es_ES |
| dc.subject | Resistencia a la fractura | es_ES |
| dc.subject | Prótesis implantosoportada | es_ES |
| dc.subject | Prótesis atornillada | es_ES |
| dc.subject | Monolithic zirconia | es_ES |
| dc.subject | Pontic design | es_ES |
| dc.subject | Fracture resistance | es_ES |
| dc.subject | Implant-supported prosthesis | es_ES |
| dc.subject | Screw-retained prosthesis | es_ES |
| dc.subject.mesh | Computer-Aided Design | * |
| dc.subject.mesh | Dental Implants | * |
| dc.subject.mesh | Zirconium | * |
| dc.subject.mesh | Dental Prosthesis, Implant-Supported | * |
| dc.subject.mesh | Denture, Partial, Fixed | * |
| dc.subject.mesh | Dental Prosthesis Design | * |
| dc.title | Influencia del diseño geométrico de los ponticos en la resistencia a la fractura de prótesis monolíticas fijas de circonio atornilladas y soportadas por implantes | es_ES |
| dc.type | info:eu-repo/semantics/doctoralThesis | es_ES |
| dc.subject.unesco | 3314.02 Prótesis | es_ES |
| dc.subject.unesco | 3213.13 Ortodoncia-Estomatología | es_ES |
| dc.subject.unesco | 3312.03 Materiales Cerámicos | es_ES |
| dc.subject.unesco | 3312.09 Resistencia de Materiales | es_ES |
| dc.identifier.doi | 10.14201/gredos.170405 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
| dc.subject.decs | diseño de prótesis dentales | * |
| dc.subject.decs | diseño asistido por ordenador | * |
| dc.subject.decs | prótesis dental con soporte por implante | * |
| dc.subject.decs | circonio | * |
| dc.subject.decs | implantes dentales | * |
| dc.subject.decs | dentadura postiza parcial fija | * |