dc.descriptionLos resultados de la presente Tesis Doctoral han sido publicados en la siguiente revista de investigación: Cruz-Jiménez S, Martínez-Alcaraz P, Flores-Fraile J, Agustín-Panadero R, Lobo-Galindo AB, Carbonell-López C, Zubizarreta-Macho Á. Evaluating the Impact of Pontic Geometry on Load to Failure and Displace-ment in Implant-Supported Monolithic Zirconia Prostheses: An In Vitro Analysis. J Funct Biomater. 2025 Feb 20;16(3):76. doi: 10.3390/jfb16030076. PMID: 40137355; PMCID: PMC11942727.es_ES
dc.description.abstract[ES] En las prótesis monoliticas de zirconia atornilladas y soportadas sobre implantes el diseño del póntico puede influir frente a la carga de fractura. Este estudio tuvo como objetivo evaluar cómo afecta el diseño del póntico en la resistencia a la fractura de dichas restauraciones. Se diseñaron cuarenta prótesis mediante soft-ware CAD dental y se dividieron en cuatro grupos (n = 10): (A) pónticos planos y anchos (10 mm de ancho, 8 mm de alto), (B) pónticos cóncavos y anchos (10 mm de ancho, 5,5 mm de alto), (C) pónticos planos y estrechos (6 mm de ancho, 8 mm de alto), y (D) pónticos cóncavos y estrechos (6 mm de ancho, 5,5 mm de alto). Todas las muestras fueron sometidas a ciclos térmicos y mecánicos, y a una carga de fractura mediante flexión en tres puntos. Las cargas máximas de fractura y los desplazamientos se analizaron mediante ANOVA unidireccional. Se observaron diferencias estadísticamente significativas entre los grupos tanto en la carga de fractura (p = 0,001) como en el desplazamiento (p = 0,002). Con los resultados obtenidos se determinó que la geometría del póntico influye de forma significativa en la resistencia a la fractura y el comportamiento frente a la deformación de las prótesis monolíticas de zirconia.es_ES
dc.description.abstract[EN] The pontic design may influence the load-to-failure performance of fixed implant-supported screw-retained monolithic zirconia prostheses. This study aimed to evaluate the effect of pontic geometry on the fracture resistance of such restorations. Forty restorations were designed using dental CAD software and divided into four groups (n = 10 each): (A) Flat + Wide-pontics with a flat contour, 10 mm in width and 8 mm in height; (B) Concave + Wide-pontics with a concave contour, 10 mm in width and 5,5 mm in height; (C) Flat + Narrow-pontics with a flat contour, 6 mm in width and 8 mm in height; and (D) Concave + Narrow-pontics with a concave contour, 6 mm in width and 5,5 mm in height. All specimens underwent thermal and mechanical cycling, followed by a fracture load test using a three-point bending setup. Maximum fracture loads and displacements were analyzed using one-way ANOVA. Statistically significant differences were observed among the groups for both load to failure (p = 0.001) and displacement (p = 0.002). These findings indicate that pontic geometry significantly influences the fracture resistance and deformation behavior of monolithic zirconia prostheses.
dc.language.isospaes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectTesis y disertaciones académicases_ES
dc.subjectUniversidad de Salamanca (España)es_ES
dc.subjectTesis Doctorales_ES
dc.subjectAcademic dissertationses_ES
dc.subjectZirconia monolíticaes_ES
dc.subjectDiseño del pónticoes_ES
dc.subjectResistencia a la fracturaes_ES
dc.subjectPrótesis implantosoportadaes_ES
dc.subjectPrótesis atornilladaes_ES
dc.subjectMonolithic zirconiaes_ES
dc.subjectPontic designes_ES
dc.subjectFracture resistancees_ES
dc.subjectImplant-supported prosthesises_ES
dc.subjectScrew-retained prosthesises_ES
dc.subject.meshComputer-Aided Design *
dc.subject.meshDental Implants *
dc.subject.meshZirconium *
dc.subject.meshDental Prosthesis, Implant-Supported *
dc.subject.meshDenture, Partial, Fixed *
dc.subject.meshDental Prosthesis Design *
dc.titleInfluencia del diseño geométrico de los ponticos en la resistencia a la fractura de prótesis monolíticas fijas de circonio atornilladas y soportadas por implanteses_ES
dc.typeinfo:eu-repo/semantics/doctoralThesises_ES
dc.subject.unesco3314.02 Prótesises_ES
dc.subject.unesco3213.13 Ortodoncia-Estomatologíaes_ES
dc.subject.unesco3312.03 Materiales Cerámicoses_ES
dc.subject.unesco3312.09 Resistencia de Materialeses_ES
dc.identifier.doi10.14201/gredos.170405
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.subject.decsdiseño de prótesis dentales *
dc.subject.decsdiseño asistido por ordenador *
dc.subject.decsprótesis dental con soporte por implante *
dc.subject.decscirconio *
dc.subject.decsimplantes dentales *
dc.subject.decsdentadura postiza parcial fija *


Arquivos deste item

Thumbnail

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Exceto quando indicado o contrário, a licença deste item é descrito como Attribution-NonCommercial-NoDerivatives 4.0 Internacional