dc.description.abstract[ES] Este estudio tuvo como objetivo evaluar la capacidad de recuperación y el posible daño en las conexiones implante-pilar ocasionado por la extracción de torni-llos de pilar fracturados mediante técnicas convencionales y de fresado. Se frac-turaron y extrajeron cuarenta tornillos insertados en implantes dentales utilizando cuatro métodos: convencional con sonda exploradora y dispositivo ultrasónico (Grupo A), sistema de fresado Phibo (Grupo B), sistema Rhein83® (Grupo C) y sistema Sanhigia® (Grupo D), todos sin irrigación. Se realizaron escaneos micro-CT antes y después de los procedimientos, generando archivos STL para el aná-lisis morfométrico del volumen de desgaste. El análisis estadístico (ANOVA) no mostró diferencias significativas en el volumen ni en el porcentaje de desgaste de las roscas internas entre los grupos, aunque la tasa de éxito en la recupera-ción de tornillos fue mayor con los sistemas de fresado (90%) frente a la técnica convencional (50%). Estos resultados sugieren que los sistemas de fresado son más eficaces para la extracción de tornillos dañados, sin que ello implique un mayor desgaste en la conexión implante-pilar. [EN] This study aimed to evaluate the retrievability and potential damage to implant-abutment connections caused by fractured abutment screw removal using con-ventional and drilling techniques. A total of forty abutment screws were randomly inserted into forty dental implants, then fractured and extracted using different removal methods: Group A employed a conventional approach utilizing an explo-ration probe and ultrasonic device without irrigation (n = 10) (Conventional); Group B used the Phibo drilling removal system without irrigation (n = 10) (Phibo); Group C utilized the Rhein83® drilling removal system without irrigation (n = 10) (Rhein83); and Group D implemented the Sanhigia® drilling removal system with-out irrigation (n = 10) (Sanhigia). Preoperative and postoperative micro-computed tomography (micro-CT) scans were performed on the dental implants, and Stand-ard Tessellation Language (STL) digital files were generated using morphometric analysis to measure wear volume. ANOVA statistical analysis was used to assess volumetric differences (mm³) and percentage ratios between the internal thread volumes of implant-abutment connections before and after the procedures. Re-sults: The study demonstrated no statistically significant differences in volumetric and percentage variations of internal threads among implant groups (Phibo, Rhein83, Sanhigia, and UT). However, the success rate for retrieving fractured abutment screws was higher (90%) with drilling systems compared to the con-ventional technique (50%). These results suggest that drilling systems are more effective for the retrieval of damaged screws. Although drilling techniques without irrigation demonstrated higher removal efficiency compared to conventional methods, both approaches resulted in similar wear volumes on the implant-abut-ment connections when extracting fractured screws.es_ES
dc.language.isospaes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationales_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es_ES
dc.subjectTesis y disertaciones académicases_ES
dc.subjectUniversidad de Salamanca (España)es_ES
dc.subjectTesis Doctorales_ES
dc.subjectAcademic dissertationses_ES
dc.subjectTornillo de pilar fracturadoes_ES
dc.subjectImplantes dentaleses_ES
dc.subjectConexión implante-pilares_ES
dc.subjectTécnicas de extracciónes_ES
dc.subjectMicrotomografía computarizadaes_ES
dc.subjectFractured abutment screwes_ES
dc.subjectDental implantses_ES
dc.subjectImplant-abutment connectiones_ES
dc.subjectRemoval techniqueses_ES
dc.subjectMicro-computed tomographyes_ES
dc.titleAnálisis comparativo de la recuperabilidad y el daño de la conexión implante-pilar de tornillos de pilar fracturados utilizando técnicas convencionales y guiadases_ES
dc.typeinfo:eu-repo/semantics/doctoralThesises_ES
dc.subject.unesco3213.13 Ortodoncia-Estomatologíaes_ES
dc.subject.unesco3213 Cirugíaes_ES
dc.identifier.doi10.14201/gredos.172270
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 International
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International