dc.identifier.citationGil González, A. B., y Vega Cruz, P. I. (2002). "Diseño y simulación de una torre de sulfitación, Informe técnico DPTOIA-IT-2002-003". Salamanca : Universidad de Salamanca.es_ES
dc.identifier.urihttp://hdl.handle.net/10366/21715es_ES
dc.identifier.urihttp://hdl.handle.net/10366/21715
dc.description.abstractEste informe recoge la metodología del diseño óptimo para procesos continuos con objeto dereducir los costes de construcción y de operación del sistema final mediante diseño integrado.La planta química de referencia está tomada de la industria azucarera (torre de sulfitación), seha descrito inicialmente su modelo matemático no-lineal. Después una planta alternativa ha sidoseleccionada para calcular de forma óptima las dimensiones de las unidades de proceso juntocon el punto estacionario de operación.Los diseños de plantas son realizados teniendo en cuenta objetivos económicos mediante lautilización de modelos no lineales. Distintas plantas han sido obtenidas para el caso particularde una torre de sulfitación, después de esto, el efecto de los diseños han sido analizadosmediante una comparativa en los costes mencionados.es_ES
dc.description.abstractThis report shows a methodology for the optimal design of continuos processes in order toreduce the construction costs and the performance costs of the final systems within an IntegratedDesign framework. A reference chemical plant from the sugar industry (a sulfitation tower) hasbeen described and a non-linear mathematical model is presented. After this, an alternativeplant have been selected in order to get the optimal dimension of the process units together witha stationary operating point.The plants designs are carried out taking into account economic objectives and using nonlinearfirst priciple models. Different plants have been obtained for the particular case of thesulfitation tower and, after this, the effect of the designs has been clearly analysed by comparingthe above mentioned costs.es_ES
dc.format.extent37 p.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.languageEspañoles_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Salamanca (España). Departamento de Informática y Automáticaes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Unported
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/
dc.subjectDiseño óptimoes_ES
dc.subjectTorre de sulfitaciónes_ES
dc.subjectReducción de costeses_ES
dc.subjectOptimal designes_ES
dc.subjectSulfitation toweres_ES
dc.titleDiseño y simulación de una torre de sulfitaciónes_ES
dc.typeinfo:eu-repo/semantics/reportes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Fichier(s) constituant ce document

Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Attribution-NonCommercial-NoDerivs 3.0 Unported
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Attribution-NonCommercial-NoDerivs 3.0 Unported