<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-15T21:39:56Z</responseDate><request verb="GetRecord" identifier="oai:gredos.usal.es:10366/155229" metadataPrefix="etdms">https://gredos.usal.es/oai/request</request><GetRecord><record><header><identifier>oai:gredos.usal.es:10366/155229</identifier><datestamp>2026-01-14T09:53:31Z</datestamp><setSpec>com_10366_4182</setSpec><setSpec>com_10366_4055</setSpec><setSpec>com_10366_3946</setSpec><setSpec>com_10366_3823</setSpec><setSpec>col_10366_4183</setSpec></header><metadata><thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.0/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.0/ http://www.ndltd.org/standards/metadata/etdms/1.0/etdms.xsd">
<title>Towards in field miniaturized liquid chromatography: Biocides in wastewater as a proof of concept</title>
<creator>Cortés-Bautista, S.</creator>
<creator>Navarro-Utiel, R.</creator>
<creator>Ballester Caudet, Ana</creator>
<creator>Campíns-Falcó, P.</creator>
<subject>Portable</subject>
<subject>Miniaturized liquid chromatography</subject>
<subject>Water analysis</subject>
<subject>Biocides</subject>
<subject>BETTER criteria</subject>
<subject>HEXAGON tool</subject>
<description>[EN] Solving and/or evaluating given problems or decision making in place and in real time is a goal of the an- alytical chemistry science. In this context, the performance of a commercial portable miniaturized liquid chromatograph (minLC) with LED UV (255 nm) detector was compared with those provided by two lab minLCs (capillary and nano) coupled on-line to in-valve in-tube solid phase microextraction (IT-SPME) with diode array detector (DAD). In addition, responses of the portable LC for in-field analysis in sev- eral conditions were tested. Besides, two evaluation tools, BETTER criteria for portability and HEXAGON pictogram for sustainability and greenness were applied for comparison purposes. The benchtop LCs pro- vided lower limits of detection (LODs) as expected, in the order of low μg/L, than those achieved by the portable LC, with LODs around mg/L for compounds covering several polarities (logKow between -1.72 and 3.82). The used portable LC gave excellent resolution, reducing the analysis time and being the consumption of solvents negligible. As a practical application, fruit washing residual waters, which contained a suitable level of concentrations of several biocides for employing the portable minLC, were analyzed and quantified from the three minLCs as a proof of concept with comparable results.</description>
<date>2024-02-02</date>
<date>2024-02-02</date>
<date>2022</date>
<type>info:eu-repo/semantics/article</type>
<identifier>S. Cortés-Bautista, R. Navarro-Utiel, A. Ballester-Caudet, P. Campíns-Falcó,&#xd;
Towards in field miniaturized liquid chromatography: Biocides in wastewater as a proof of concept,&#xd;
Journal of Chromatography A,&#xd;
Volume 1673,&#xd;
2022,&#xd;
463119,&#xd;
ISSN 0021-9673,&#xd;
https://doi.org/10.1016/j.chroma.2022.463119.&#xd;
(https://www.sciencedirect.com/science/article/pii/S0021967322003120)</identifier>
<identifier>0021-9673</identifier>
<identifier>http://hdl.handle.net/10366/155229</identifier>
<identifier>10.1016/j.chroma.2022.463119</identifier>
<language>eng</language>
<relation>https://doi.org/10.1016/j.chroma.2022.463119</relation>
<rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</rights>
<rights>info:eu-repo/semantics/openAccess</rights>
<rights>Attribution-NonCommercial-NoDerivatives 4.0 Internacional</rights>
<publisher>Elsevier</publisher>
</thesis></metadata></record></GetRecord></OAI-PMH>