<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-15T23:27:34Z</responseDate><request verb="GetRecord" identifier="oai:gredos.usal.es:10366/157677" metadataPrefix="rdf">https://gredos.usal.es/oai/request</request><GetRecord><record><header><identifier>oai:gredos.usal.es:10366/157677</identifier><datestamp>2025-04-30T20:08:08Z</datestamp><setSpec>com_10366_4311</setSpec><setSpec>com_10366_4200</setSpec><setSpec>com_10366_3946</setSpec><setSpec>com_10366_3823</setSpec><setSpec>col_10366_4312</setSpec></header><metadata><rdf:RDF xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
<ow:Publication rdf:about="oai:gredos.usal.es:10366/157677">
<dc:title>Surface electromyography in ballistic movement: a comparative methodological analysis from taekwondo athletes</dc:title>
<dc:creator>Barramuño, Mauricio</dc:creator>
<dc:creator>Valdés Badilla, Pablo</dc:creator>
<dc:creator>Fonseca, Fernando Taveira da</dc:creator>
<dc:creator>Gálvez García, Germán</dc:creator>
<dc:subject>Combat sports</dc:subject>
<dc:subject>Electromyography</dc:subject>
<dc:subject>Muscle activity</dc:subject>
<dc:subject>Data processing</dc:subject>
<dc:subject>Deportes de combate</dc:subject>
<dc:subject>Electromiografía</dc:subject>
<dc:subject>Actividad muscular</dc:subject>
<dc:subject>Procesamiento de datos</dc:subject>
<dc:description>[EN] Surface electromyography (sEMG) signal processing methods used to assess combat sports are heterogeneous.&#xd;
This research aims to compare the electromyography peak (peak EMG) in taekwondo athletes with five processing methods.&#xd;
Secondarily, the coefficient of variation (CV) and the noise percentage regarding the peak EMG (NPRP) were compared. The&#xd;
sEMG record of eight leg muscles of sixteen athletes (12 male and 4 female, ages 20.31+4.1 years) was consulted. The&#xd;
processing methods were: a) Smoothing 1, b) Smoothing 2, c) Root mean square (RMS) 1, d) RMS 2, and e) Empirical mode&#xd;
decomposition (EMD). Results indicate that the peak EMG differs among Smoothing 1 vs. EMD; Smoothing 2 vs. EMD;&#xd;
Smoothing 1 vs. RMS 2; Smoothing 2 vs. RMS 2; Smoothing 1 vs. RMS 1; RMS 1 vs. RMS 2; RMS 1 vs. EMD, and RMS 2 vs.&#xd;
EMD. For all cases p&lt;.05 in seven of the eight muscles studied. No differences were found for the CV. The EMD NPRP was&#xd;
lower than the other methods analyzed (p&lt;.05). As a conclusion, there are differences among the studied methods and&#xd;
should be considered when interpreting the peak EMG. The EMD seems to be a useful alternative for reducing noise and&#xd;
artifact movement.&#xd;
[ES]Los métodos de procesamiento de señales de electromiografía de superficie (sEMG) utilizados para evaluar los&#xd;
deportes de combate son heterogéneos. Esta investigación tiene como objetivo comparar el pico de electromiografía (pico&#xd;
EMG) en atletas de taekwondo con cinco métodos de procesamiento. En segundo lugar, se compararon tanto el coeficiente&#xd;
de variación (CV) como el porcentaje de ruido con respecto al pico EMG (NPRP). Se consultó el registro sEMG de ocho&#xd;
músculos de las piernas de dieciséis atletas (12 hombres y 4 mujeres, edades 20,31+4,1). Los métodos de procesamiento&#xd;
fueron: a) Suavizado 1, b) Suavizado 2, c) Raíz cuadrada media (RMS) 1, d) RMS 2 y e) Descomposición en modo empírico&#xd;
(EMD). Los resultados indican que el pico de EMG difiere entre el suavizado vs. EMD; Suavizado 2 vs. EMD; Suavizado 1 vs.&#xd;
RMS 2; Suavizado 2 vs. RMS 2; Suavizado 1 vs. RMS 1; RMS 1 vs. RMS 2; RMS 1 vs. EMD y RMS 2 vs. EMD. Para todos los&#xd;
casos p &lt;.05 en siete de los ocho músculos estudiados. No se encontraron diferencias para el CV. El EMD NPRP fue menor&#xd;
que los otros métodos analizados (p &lt;.05). En conclusión, existen diferencias entre los métodos estudiados y deben tenerse&#xd;
en cuenta al interpretar el pico EMG. El EMD parece ser una alternativa útil para reducir el ruido y el movimiento de&#xd;
artefactos.</dc:description>
<dc:date>2024-05-06T15:25:40Z</dc:date>
<dc:date>2024-05-06T15:25:40Z</dc:date>
<dc:date>2022</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>1579-1726</dc:identifier>
<dc:identifier>1988-2041</dc:identifier>
<dc:identifier>http://hdl.handle.net/10366/157677</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:rights>Attribution-NonCommercial-NoDerivatives 4.0 Internacional</dc:rights>
</ow:Publication>
</rdf:RDF></metadata></record></GetRecord></OAI-PMH>