<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-16T03:54:26Z</responseDate><request verb="GetRecord" identifier="oai:gredos.usal.es:10366/162162" metadataPrefix="dim">https://gredos.usal.es/oai/request</request><GetRecord><record><header><identifier>oai:gredos.usal.es:10366/162162</identifier><datestamp>2025-04-30T19:32:55Z</datestamp><setSpec>com_10366_4001</setSpec><setSpec>com_10366_3947</setSpec><setSpec>com_10366_3946</setSpec><setSpec>com_10366_3823</setSpec><setSpec>col_10366_4002</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="c210fc24-fbd6-41db-8671-b03f6b448951" confidence="500" orcid_id="">Peña Lorenzo, Diego</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="2153" confidence="600" orcid_id="">Rebollo Díaz, Noemí</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="3a4c914d-bad8-4199-a36f-a90b0c7255ad" confidence="500" orcid_id="">Sanchez Hernández, José Germán</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="2684" confidence="600" orcid_id="">Zarzuelo Castañeda, Aránzazu</dim:field>
<dim:field mdschema="dc" element="date" qualifier="accessioned">2025-01-21T11:30:06Z</dim:field>
<dim:field mdschema="dc" element="date" qualifier="available">2025-01-21T11:30:06Z</dim:field>
<dim:field mdschema="dc" element="date" qualifier="issued">2021</dim:field>
<dim:field mdschema="dc" element="date" qualifier="embargoEndDate">2099-09-09</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="issn">0004-5632</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10366/162162</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="doi">10.1177/00045632211041887</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="essn">1758-1001</dim:field>
<dim:field mdschema="dc" element="description" qualifier="abstract" lang="es_ES">Therapeutic drug monitoring (TDM) of voriconazole is recommended for personalizing doses. The objective of this study was to compare the enzyme immunoassay developed by ARKTM Diagnostics Inc. for the quantification of voriconazole adapted to the Architect C4000 autoanalyzer (Abbott®) with ultra-performance liquid chromatography using ultraviolet detector (UPLC-UV) method. Materials and Methods: Linearity, precision and accuracy of both methods were validated according to the Food and Drug Administration (FDA) and European Medicines Agency guidelines. The limit of quantification (LOQ) of the UPLC-UV method was determined experimentally. Both methods were applied to the analysis of 62 samples from patients. Correlation was evaluated by Passing-Bablok analysis and the concordance by the Bland–Altman method. Dosage recommendations were generated; the discordances according to the technique were evaluated. Results: All validation parameters determined for UPLC-UV met the criteria set out and LOQ of 0.1 μg/mL was established. However, when the enzyme immunoassay was used to determine concentrations ≤1 μg/ml, CVs were >20%. A linear correlation between both methods was found. However, an overestimation of immunoassay (systematic error of 0.39 μg/mL) was detected. In 11.3% of the samples, the differences in concentrations when they were determined by different techniques would imply a different therapeutic regime. These samples had concentrations close to 1 μg/mL. Conclusion: Although both techniques can be used for TDM of voriconazole, when a value close to the lower limit of the therapeutic range is determined by the ARKTM immunoassay, it would be better to verify the result by a non-automated technique to avoid possible underdosing.</dim:field>
<dim:field mdschema="dc" element="language" qualifier="iso" lang="es_ES">eng</dim:field>
<dim:field mdschema="dc" element="rights">Attribution-NonCommercial-NoDerivatives 4.0 Internacional</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="uri">http://creativecommons.org/licenses/by-nc-nd/4.0/</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="accessRights" lang="es_ES">info:eu-repo/semantics/embargoedAccess</dim:field>
<dim:field mdschema="dc" element="subject" lang="es_ES">Voriconazole</dim:field>
<dim:field mdschema="dc" element="subject" lang="es_ES">Monitoring</dim:field>
<dim:field mdschema="dc" element="subject" lang="es_ES">Immunoassay</dim:field>
<dim:field mdschema="dc" element="subject" lang="es_ES">UPLC</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="unesco" lang="es_ES">2301 Química Analítica</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="unesco" lang="es_ES">3201 Ciencias Clínicas</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="decs" lang="*" authority="25561" confidence="500">métodos analíticos</dim:field>
<dim:field mdschema="dc" element="title" lang="es_ES">Comparison of ultra-performance liquid chromatography and ARK immunoassay for therapeutic drug monitoring of voriconazole</dim:field>
<dim:field mdschema="dc" element="type" lang="es_ES">info:eu-repo/semantics/article</dim:field>
<dim:field mdschema="dc" element="type" qualifier="hasVersion" lang="es_ES">info:eu-repo/semantics/publishedVersion</dim:field>
<dim:field mdschema="dc" element="relation" qualifier="publishversion" lang="es_ES">https://doi.org/10.1177/00045632211041887</dim:field>
<dim:field mdschema="dc" element="journal" qualifier="title" lang="es_ES">Annals of Clinical Biochemistry: International Journal of Laboratory Medicine</dim:field>
<dim:field mdschema="dc" element="volume" qualifier="number" lang="es_ES">58</dim:field>
<dim:field mdschema="dc" element="issue" qualifier="number" lang="es_ES">6</dim:field>
<dim:field mdschema="dc" element="page" qualifier="initial" lang="es_ES">657</dim:field>
<dim:field mdschema="dc" element="page" qualifier="final" lang="es_ES">660</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>