<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T10:43:44Z</responseDate><request verb="GetRecord" identifier="oai:gredos.usal.es:10366/162169" metadataPrefix="mods">https://gredos.usal.es/oai/request</request><GetRecord><record><header><identifier>oai:gredos.usal.es:10366/162169</identifier><datestamp>2025-04-30T19:49:30Z</datestamp><setSpec>com_10366_4182</setSpec><setSpec>com_10366_4055</setSpec><setSpec>com_10366_3946</setSpec><setSpec>com_10366_3823</setSpec><setSpec>col_10366_4183</setSpec></header><metadata><mods:mods xmlns:mods="http://www.loc.gov/mods/v3" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:namePart>González Mariño, Iria</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Casas Ferreira, Ana María</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Nogal Sánchez, Miguel del</mods:namePart>
</mods:name>
<mods:name>
<mods:namePart>Pérez Pavón, José Luis</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2025-01-21T11:47:33Z</mods:dateAvailable>
</mods:extension>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2025-01-21T11:47:33Z</mods:dateAccessioned>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2023</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="citation">Iria González-Mariño, Ana María Casas-Ferreira, Miguel del Nogal Sánchez, José Luis Pérez Pavón, Use of a guard column coupled to mass spectrometry as a fast semi-quantitative methodology for the determination of plasticizer metabolites in urine, Journal of Chromatography A, Volume 1690, 2023, 463788, ISSN 0021-9673, https://doi.org/10.1016/j.chroma.2023.463788. (https://www.sciencedirect.com/science/article/pii/S002196732300016X)</mods:identifier>
<mods:identifier type="issn">0021-9673</mods:identifier>
<mods:identifier type="uri">http://hdl.handle.net/10366/162169</mods:identifier>
<mods:identifier type="doi">10.1016/j.chroma.2023.463788</mods:identifier>
<mods:abstract>[EN]or the first time, a very simple and fast method combining the use of a guard column coupled to tandem mass spectrometry (guard column-MS/MS) has been proposed for the determination of plasticizer metabolites in urine. Briefly, samples (1.0 mL) were submitted to enzymatic hydrolysis for 10 min, filtered, diluted 1/10 v/v with ultrapure water and directly injected into the system. A fast run of only 2 min (3 min including the injection cycle) allowed the determination of 19 analytes. Enzymatic hydrolysis, filtering material, and guard column-MS/MS conditions were optimized. Intra-day precision at the low-level concentration (expressed as relative standard deviation, %RSD) obtained from the analysis of synthetic urine samples varied between 11 and 20%. Limits of quantification ranged from 2.8 to 60 ng/mL. Trueness values, calculated as apparent recoveries, ranged from 70 to 135%. To correct for matrix effects, analyte concentrations in real urine were quantified by the standard addition method. To confirm the results obtained by guard column-MS/MS, an ultra(high)-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was also applied (total chromatographic run time 17 min, including column re-equilibration). Concentrations measured with both methods were in good agreement. Hence, we propose the use of guard column-MS/MS to analyse a large number samples in a very short time (semi-quantification), and apply the chromatographic analysis only to those samples with levels close to/higher than the concentrations equivalent to the safe maximum daily intakes of the parent compounds (confirmation). This double strategy (semi-quantification by guard column-MS/MS and confirmation-when needed-by UHPLC-MS/MS) implies important savings in time and money.</mods:abstract>
<mods:language>
<mods:languageTerm>eng</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">http://creativecommons.org/licenses/by-nc-nd/4.0/</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">info:eu-repo/semantics/openAccess</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">Attribution-NonCommercial-NoDerivatives 4.0 Internacional</mods:accessCondition>
<mods:subject>
<mods:topic>Phthalate metabolites</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Urine</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Guard column</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Tandem mass spectrometry</mods:topic>
</mods:subject>
<mods:subject>
<mods:topic>Ultra(high)-performance liquid chromatography</mods:topic>
</mods:subject>
<mods:titleInfo>
<mods:title>Use of a guard column coupled to mass spectrometry as a fast semi-quantitative methodology for the determination of plasticizer metabolites in urine</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/article</mods:genre>