Show simple item record

dc.contributor.authorPolo Ferrero, Luis
dc.contributor.authorSánchez Tocino, M. Luz 
dc.contributor.authorDávila Marcos, Arturo
dc.contributor.authorCarrera Villegas, Marta Beatriz
dc.contributor.authorSánchez Sánchez, María Carmen 
dc.contributor.authorMéndez Sánchez, Roberto 
dc.date.accessioned2025-06-13T07:11:52Z
dc.date.available2025-06-13T07:11:52Z
dc.date.issued2025
dc.identifier.citationPolo-Ferrero, L.; Sánchez- Tocino, M.L.; Dávila-Marcos, A.; Carrera-Villegas, M.B.; Sánchez- Sánchez, M.C.; Méndez-Sánchez, R. Reliability and Validity of the Linear Transducer “ADR Encoder” for Measuring Power and Speed of the Sit-to-Stand Tests in Older Adults. Diagnostics 2025, 15, 1475. https://doi.org/10.3390/ diagnostics15121475es_ES
dc.identifier.urihttp://hdl.handle.net/10366/165973
dc.description.abstractBackground/Objectives: Lower-limb muscle function is traditionally assessed with tests like the five times sit-to-stand test (5STS) and the 30-s chair stand test (30CS). The ADR Encoder, a linear transducer, measures power and velocity during the sit-to-stand test. This study aimed to validate its use as functional indicators of muscle function in older adults. Methods: A cross-sectional study with 114 participants (mean age: 72.92 ± 4.97 years) was conducted. The 5STS, 30CS, power, and speed were measured using the ADR Encoder. Participants were categorized into frail, pre-frail, and robust groups according to the FRAIL Scale. Criterion, intraobserver, and interobserver validity were assessed. Results: Strong correlations (r > 0.7; p < 0.001) were found between power, speed, and both 5STS and 30CS. The interobserver intraclass correlation coefficient (ICC) for speed was 0.90 and the intraobserver ICC was 0.85. For power, the interobserver ICC was 0.88 and the intraobserver ICC was 0.79, all statistically significant (p < 0.001). Significant differences in power (7.78 W vs. 11.26 W; p < 0.001) and speed (0.40 m/s vs. 0.58 m/s; p < 0.001) were observed between frail and non-frail participants. Conclusions: The ADR Encoder is a valid, reliable tool for measuring power and speed in older adults. Its strong correlations with the 5STS and 30CS demonstrate its clinical relevance, with high reproducibility across observers and time points. Its application in diverse clinical and community settings could broaden its utility in geriatric functional assessment.es_ES
dc.language.isoenges_ES
dc.publisherhttps://www.mdpi.com/2075-4418/15/12/1475es_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectagedes_ES
dc.subjectfrailtyes_ES
dc.subjectgeriatric assessmentes_ES
dc.subjectmuscle strengthes_ES
dc.subjectreproducibility of resultses_ES
dc.subjectvalidation studyes_ES
dc.subjectphysical fitnesses_ES
dc.subjectcross-sectional studieses_ES
dc.subject.meshMuscle Strength *
dc.subject.meshAged *
dc.subject.meshGeriatric Assessment *
dc.subject.meshReproducibility of Results *
dc.subject.meshCross-Sectional Studies *
dc.subject.meshPhysical Fitness *
dc.titleReliability and validity of the linear transducer “ADR Encoder” for measuring power and speed of the sit-to-stand tests in older adultses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.3390/diagnostics15121475es_ES
dc.identifier.doi10.3390/diagnostics15121475
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.audience.educationLevel
dc.identifier.essn2075-4418
dc.journal.titleDiagnosticses_ES
dc.volume.number15es_ES
dc.issue.number12es_ES
dc.page.initial1475es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.subject.decsfuerza muscular *
dc.subject.decsreproducibilidad de resultados *
dc.subject.decsaptitud física *
dc.subject.decsestudios transversales *
dc.subject.decsanciano *
dc.subject.decsevaluación geriátrica *


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional