Show simple item record

dc.contributor.authorLi, Zhexu
dc.contributor.authorGonzález Ayala, Julián 
dc.contributor.authorHanxin, Yang
dc.contributor.authorGuo, Juncheng
dc.contributor.authorCalvo Hernández, Antonio 
dc.date.accessioned2022-01-20T09:03:53Z
dc.date.available2022-01-20T09:03:53Z
dc.date.issued2022-01
dc.identifier.issn1751-8113
dc.identifier.urihttp://hdl.handle.net/10366/148364
dc.description.abstract[EN]In the present paper, a general non-combined model of three-terminal refrigerator beyond specific heat transfer mechanisms is established based on the low-dissipation assumption. The relation between the optimized cooling power and the corresponding coefficient of performance (COP) is analytically derived, according to which the COP at maximum cooling power (CMP) can be further determined. At two dissipation asymmetry limits, upper and lower bounds of CMP are obtained and found to be in good agreement with experimental and simulated results. Additionally, comparison of the obtained bounds with previous combined model is presented. In particular it is found that the upper bounds are the same, whereas the lower bounds are quite different. This feature indicates that the claimed universal equivalence for the combined and non-combined models under endoreversible assumption is invalid within the frame of low-dissipation assumption. Then, the equivalence between various finite-time thermodynamic models needs to be reevaluated regarding multi-terminal systems. Moreover, the correlation between the combined and non-combined models is further revealed by the derivation of the equivalentes_ES
dc.description.sponsorshipJGA thanks financial support for a postdoctoral contract from University of Salamanca under Program IIes_ES
dc.format.mimetypeapplication/pdf
dc.language.isoenges_ES
dc.publisherIOP Publishinges_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectfinite-time cycle, low-dissipation model, three-terminal refrigerator, performance bounds, comparative analyseses_ES
dc.titleLow-dissipation model of three-terminal refrigerator: performance bounds and comparative analyseses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttp://doi.org/10.1088/1751-8121/ac47b0es_ES
dc.identifier.doi10.1088/1751-8121/ac47b0
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.essn1751-8121
dc.journal.titleJournal of Physics A: Mathematical and Theoreticales_ES
dc.volume.number55es_ES
dc.issue.number6es_ES
dc.page.initial065001es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES