Mostra i principali dati dell'item
| dc.contributor.author | Cortés-Bautista, S. | |
| dc.contributor.author | Navarro-Utiel, R. | |
| dc.contributor.author | Ballester Caudet, Ana | |
| dc.contributor.author | Campíns-Falcó, P. | |
| dc.date.accessioned | 2024-02-02T12:43:28Z | |
| dc.date.available | 2024-02-02T12:43:28Z | |
| dc.date.issued | 2022 | |
| dc.identifier.citation | S. Cortés-Bautista, R. Navarro-Utiel, A. Ballester-Caudet, P. Campíns-Falcó, Towards in field miniaturized liquid chromatography: Biocides in wastewater as a proof of concept, Journal of Chromatography A, Volume 1673, 2022, 463119, ISSN 0021-9673, https://doi.org/10.1016/j.chroma.2022.463119. (https://www.sciencedirect.com/science/article/pii/S0021967322003120) | |
| dc.identifier.issn | 0021-9673 | |
| dc.identifier.uri | http://hdl.handle.net/10366/155229 | |
| dc.description.abstract | [EN] Solving and/or evaluating given problems or decision making in place and in real time is a goal of the an- alytical chemistry science. In this context, the performance of a commercial portable miniaturized liquid chromatograph (minLC) with LED UV (255 nm) detector was compared with those provided by two lab minLCs (capillary and nano) coupled on-line to in-valve in-tube solid phase microextraction (IT-SPME) with diode array detector (DAD). In addition, responses of the portable LC for in-field analysis in sev- eral conditions were tested. Besides, two evaluation tools, BETTER criteria for portability and HEXAGON pictogram for sustainability and greenness were applied for comparison purposes. The benchtop LCs pro- vided lower limits of detection (LODs) as expected, in the order of low μg/L, than those achieved by the portable LC, with LODs around mg/L for compounds covering several polarities (logKow between -1.72 and 3.82). The used portable LC gave excellent resolution, reducing the analysis time and being the consumption of solvents negligible. As a practical application, fruit washing residual waters, which contained a suitable level of concentrations of several biocides for employing the portable minLC, were analyzed and quantified from the three minLCs as a proof of concept with comparable results. | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | Elsevier | es_ES |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.subject | Portable | es_ES |
| dc.subject | Miniaturized liquid chromatography | es_ES |
| dc.subject | Water analysis | es_ES |
| dc.subject | Biocides | es_ES |
| dc.subject | BETTER criteria | es_ES |
| dc.subject | HEXAGON tool | es_ES |
| dc.title | Towards in field miniaturized liquid chromatography: Biocides in wastewater as a proof of concept | es_ES |
| dc.type | info:eu-repo/semantics/article | es_ES |
| dc.relation.publishversion | https://doi.org/10.1016/j.chroma.2022.463119 | es_ES |
| dc.subject.unesco | 2301 Química Analítica | es_ES |
| dc.identifier.doi | 10.1016/j.chroma.2022.463119 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
| dc.journal.title | Journal of Chromatography A | es_ES |
| dc.volume.number | 1673 | es_ES |
| dc.page.initial | 463119 | es_ES |
| dc.type.hasVersion | info:eu-repo/semantics/publishedVersion | es_ES |
Files in questo item
Questo item appare nelle seguenti collezioni
-
DQANB. Artículos [108]








