Compartir
Título
Evaluation of the selectivity of molecularly imprinted polymer cartridges for nitroimidazoles. Application to the simultaneous extraction of nitroimidazoles and benzimidazoles from samples of animal origin
Autor(es)
Palabras clave
MISPE
HPLC-MS/MS
Nitroimidazoles
Benzimidazoles
Clasificación UNESCO
2301 Química Analítica
Fecha de publicación
2022
Editor
Elsevier
Citación
Bustamante-Rangel, M., Rodríguez-Gonzalo, E., & Milagros Delgado-Zamareño, M. (2022). Evaluation of the selectivity of molecularly imprinted polymer cartridges for nitroimidazoles. Application to the simultaneous extraction of nitroimidazoles and benzimidazoles from samples of animal origin. Microchemical Journal, 172, 107000. https://doi.org/10.1016/j.microc.2021.107000
Resumen
[EN] In this work the selectivity of commercial molecularly imprinted polymer (MIP) cartridges for nitroimidazoles
has been evaluated. For this, a sample treatment based on molecularly imprinted solid phase extraction (MISPE)
has been developed and applied to the simultaneous extraction of nitroimidazoles and benzimidazoles. These
cartridges were compared with other sorbents commonly used for the solid phase extraction (SPE) of veterinary
drugs such as C18, hydrophilic/lipophilic balanced (HLB), and strong cation exchange (SCX). Analysis of the
extracts was carried out by HPLC-MS/MS. The use of MIP cartridges provided good results for all nitroimidazoles
and for most of the benzimidazoles studied (except for the most apolar analytes), both in terms of recovery and
precision and in the cleaning of the extracts. Thus, although MIPs have been designed to specifically bind to a
target molecule, i.e., nitroimidazoles, they are able to extract other analytes, such as benzimidazoles, with high
efficiency. The developed method was applied to the determination of four nitroimidazoles and ten benzimidazoles in samples of animal origin. All nitroimidazoles and eight of the benzimidazoles were successfully
determined. Validation of the method afforded values in the range of 91–111% for the recovery studies. The
analysis of intra-day and inter-day precision showed relative standard deviation values lower than 9.5 % and 12
% respectively. These results indicate that the proposed method is suitable for the determination of nitroimidazoles and benzimidazoles in samples of animal origin
URI
ISSN
0026-265X
DOI
10.1016/J.MICROC.2021.107000
Versión del editor
Aparece en las colecciones
- DQANB. Artículos [108]
Patrocinador
Publicación en abierto financiada por la Universidad de Salamanca como participante en el Acuerdo Transformativo CRUE-CSIC con Elsevier, 2021-2024













