Afficher la notice abrégée

dc.contributor.authorGonzález Mariño, Iria 
dc.contributor.authorCasas Ferreira, Ana María 
dc.contributor.authorNogal Sánchez, Miguel del 
dc.contributor.authorPérez Pavón, José Luis 
dc.date.accessioned2025-01-21T11:47:33Z
dc.date.available2025-01-21T11:47:33Z
dc.date.issued2023
dc.identifier.citationIria González-Mariño, Ana María Casas-Ferreira, Miguel del Nogal Sánchez, José Luis Pérez Pavón, Use of a guard column coupled to mass spectrometry as a fast semi-quantitative methodology for the determination of plasticizer metabolites in urine, Journal of Chromatography A, Volume 1690, 2023, 463788, ISSN 0021-9673, https://doi.org/10.1016/j.chroma.2023.463788. (https://www.sciencedirect.com/science/article/pii/S002196732300016X)es_ES
dc.identifier.issn0021-9673
dc.identifier.urihttp://hdl.handle.net/10366/162169
dc.description.abstract[EN]or the first time, a very simple and fast method combining the use of a guard column coupled to tandem mass spectrometry (guard column-MS/MS) has been proposed for the determination of plasticizer metabolites in urine. Briefly, samples (1.0 mL) were submitted to enzymatic hydrolysis for 10 min, filtered, diluted 1/10 v/v with ultrapure water and directly injected into the system. A fast run of only 2 min (3 min including the injection cycle) allowed the determination of 19 analytes. Enzymatic hydrolysis, filtering material, and guard column-MS/MS conditions were optimized. Intra-day precision at the low-level concentration (expressed as relative standard deviation, %RSD) obtained from the analysis of synthetic urine samples varied between 11 and 20%. Limits of quantification ranged from 2.8 to 60 ng/mL. Trueness values, calculated as apparent recoveries, ranged from 70 to 135%. To correct for matrix effects, analyte concentrations in real urine were quantified by the standard addition method. To confirm the results obtained by guard column-MS/MS, an ultra(high)-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was also applied (total chromatographic run time 17 min, including column re-equilibration). Concentrations measured with both methods were in good agreement. Hence, we propose the use of guard column-MS/MS to analyse a large number samples in a very short time (semi-quantification), and apply the chromatographic analysis only to those samples with levels close to/higher than the concentrations equivalent to the safe maximum daily intakes of the parent compounds (confirmation). This double strategy (semi-quantification by guard column-MS/MS and confirmation-when needed-by UHPLC-MS/MS) implies important savings in time and money.es_ES
dc.description.sponsorshipMinisterio de Economía y Competitividad Junta de Castilla y León Universidad de Salamanca Fundación Manuel Solórzano Barrusoes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectPhthalate metaboliteses_ES
dc.subjectUrinees_ES
dc.subjectGuard columnes_ES
dc.subjectTandem mass spectrometryes_ES
dc.subjectUltra(high)-performance liquid chromatographyes_ES
dc.titleUse of a guard column coupled to mass spectrometry as a fast semi-quantitative methodology for the determination of plasticizer metabolites in urinees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.1016/j.chroma.2023.463788es_ES
dc.subject.unesco2301 Química Analíticaes_ES
dc.identifier.doi10.1016/j.chroma.2023.463788
dc.relation.projectIDPID2021–127679NB-I00es_ES
dc.relation.projectIDSA111P20es_ES
dc.relation.projectIDPIC2–2020–16es_ES
dc.relation.projectIDFS/4–2019es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.journal.titleJournal of Chromatography Aes_ES
dc.volume.number1690es_ES
dc.page.initial463788es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES
dc.description.projectPublicación en abierto financiada por la Universidad de Salamanca como participante en el Acuerdo Transformativo CRUE-CSIC con Elsevier, 2021-2024es_ES


Fichier(s) constituant ce document

Thumbnail
Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Attribution-NonCommercial-NoDerivatives 4.0 Internacional