Mostrar el registro sencillo del ítem

dc.contributor.authorMena Álvarez, Jesús
dc.contributor.authorRuiz Barrio, María
dc.contributor.authorQuispe López, Norberto 
dc.contributor.authorde Pedro Muñoz, Ana
dc.contributor.authorRico-Romano, C.
dc.date.accessioned2025-12-09T08:56:24Z
dc.date.available2025-12-09T08:56:24Z
dc.date.issued2022
dc.identifier.citationMena-Álvarez, J., Ruiz-Barrio, M., Quispe-López, N., de Pedro-Muñoz, A., & Rico-Romano, C. (2022). Comparative Analysis of Temperature Variation with Three Continuous Wave Obturation Systems in Endodontics: An In Vitro Study. Applied Sciences, 12(12), 6229. https://doi.org/10.3390/APP12126229es_ES
dc.identifier.urihttp://hdl.handle.net/10366/168154
dc.description.abstract[EN]Abstract: The aim of this study was to assess temperature changes with different continuous wave obturation systems when downpacking to 2 mm and 4 mm from the apical foramen in an open system not simulating the surrounding biological structures at body temperature. Sixty single-rooted teeth were divided into three groups: (A) Dia-Duo® (DiaDent Group International, Cheongju-si, Korea), (B) Elements Free® (Kerr Corporation, Orange, CA, USA) and (C) Calamus® (Dentsply Sirona, Ballaigues, Switzerland). The root canals were instrumented with Protaper Gold (Dentsply Sirona, Ballaigues, Switzerland) to size F2 (25.08). The root canals were filled by a continuous wave using an AH Plus® sealer (Dentsply Sirona). Temperatures during the obturation procedure were measured by a thermal imaging camera (Testo 875-1®) perpendicular to a vice where the teeth were held at -2 mm and -4 mm from the apical foramen. Comparisons were made by applying Student’s t-test and ANOVA (p = 0.05). The continuous wave technique at -2 mm with the Dia-Duo system® emitted average temperatures of 37.3 C, Elements Free® emitted 39.85 C and Calamus® emitted 40.16 C. At -4 mm, the Dia-Duo system® emitted average temperatures of 34.81 C, Elements Free® emitted 33.73 C and Calamus® emitted 32.91 C. There were significant differences between continuous waves at -2 mm and at -4 mm (p < 0.05). Dia-Duo® was the only system that did not present significant differences between the two lengths (p = 0.197). Regarding the heat emitted, the best system was Elements Free®, since, at -2 mm, it emitted the highest temperature without going above 47 C. The Dia-Duo® system had lower temperatures. It could be concluded that not all systems transmit the same temperature to the apex and, therefore, to the periapical tissues. The surrounding conditions, such as temperature and humidity, have not been considered in this study.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectContinuous wave techniquees_ES
dc.subjectEndodontic treatmentes_ES
dc.subjectGutta-perchaes_ES
dc.subjectRoot canal obturationes_ES
dc.subjectTemperaturees_ES
dc.subject.meshEndodontics *
dc.subject.meshGutta-Percha *
dc.subject.meshRoot Canal Obturation *
dc.titleComparative analysis of temperature variation with three continuous wave obturation systems in endodontics: An in vitro studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.3390/APP12126229es_ES
dc.identifier.doi10.3390/app12126229
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.identifier.essn2076-3417
dc.journal.titleApplied Scienceses_ES
dc.volume.number12es_ES
dc.issue.number12es_ES
dc.page.initial6229es_ES
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES
dc.subject.decsendodoncia *
dc.subject.decsgutapercha *
dc.subject.decsobturación del conducto radicular *


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional