Mostra i principali dati dell'item

dc.contributor.authorMartín Santos, Patricia 
dc.contributor.authorJiménez Carracedo, Camilo
dc.contributor.authorNogal Sánchez, Miguel del 
dc.contributor.authorPérez Pavón, José Luis 
dc.contributor.authorMoreno Cordero, Bernardo 
dc.date.accessioned2026-01-09T12:59:51Z
dc.date.available2026-01-09T12:59:51Z
dc.date.issued2020
dc.identifier.citationPatricia Martín Santos, Camilo Jiménez Carracedo, Miguel del Nogal Sánchez, José Luis Pérez Pavón, Bernardo Moreno Cordero, A sensitive and automatic method based on microextraction by packed sorbents for the determination of polycyclic aromatic hydrocarbons in saliva samples, Microchemical Journal, Volume 152, 2020, 104274, ISSN 0026-265X, https://doi.org/10.1016/j.microc.2019.104274. (https://www.sciencedirect.com/science/article/pii/S0026265X19315607)es_ES
dc.identifier.issn0026-265X
dc.identifier.urihttp://hdl.handle.net/10366/168605
dc.description.abstract[EN]A sensitive method for the quantification of polycyclic aromatic hydrocarbons (PAHs) in saliva samples is proposed. The method is based on the use of microextraction by packed sorbents (MEPS), injection with programmed temperature vaporizer (PTV), gas chromatography (GC) and mass spectrometry with a single quadrupole (MS). As far as we know, the MEPS technique has not been used to date for the analysis of PAHs in saliva samples. Sample treatment carried out only involves centrifugation and filtration of the saliva sample, which is subjected to the MEPS process without dilution. Standard addition was used as a calibration strategy, due to the matrix effect found using ultrapure water and among the different saliva samples. Nine saliva samples were analysed and phenanthrene was found (15 ± 6 ng L−1) in one of them. To confirm the accuracy of the method, the concentrations added in the standard additions were compared with the value predicted by the calibration model. The values ranged between 78 and 123%. The limits of detection (LOD) found in the saliva samples ranged between 4.6 and 79 ng L−1 and the repeatability and reproducibility were always equal to or lower than 10 and 17%, respectively. The main advantage of the proposed methodology over the existing ones is the complete automation of the analysis process (extraction, separation and detection). Once the saliva sample is placed in the vial, the entire process occurs on-line.es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMicroextraction by packed sorbentses_ES
dc.subjectProgrammed temperature vaporizeres_ES
dc.subjectGas chromatographyes_ES
dc.subjectMass spectrometryes_ES
dc.subjectPolycyclic aromatic hydrocarbonses_ES
dc.subjectSaliva sampleses_ES
dc.titleA sensitive and automatic method based on microextraction by packed sorbents for the determination of polycyclic aromatic hydrocarbons in saliva sampleses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publishversionhttps://doi.org/10.1016/j.microc.2019.104274es_ES
dc.identifier.doi10.1016/j.microc.2019.104274
dc.relation.projectIDSpanish Ministry of Economy and Competitiveness (CTQ2017–87886-P/BQU)es_ES
dc.relation.projectIDCouncil of Education and Culture of the Regional Government of Castile and Leon (SA055P17)es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.journal.titleMicrochemical Journales_ES
dc.volume.number152es_ES
dc.page.initial104274es_ES
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.description.projectP. Martín Santos wishes to express her gratitude to the University of Salamanca for her predoctoral fellowshipes_ES


Files in questo item

Thumbnail

Questo item appare nelle seguenti collezioni

Mostra i principali dati dell'item

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional